From 16da1c68f220470dc081df6330ac128cfd36aea2 Mon Sep 17 00:00:00 2001 From: ETWen Date: Wed, 21 Oct 2026 09:01:55 +0800 Subject: [PATCH] docs: Record V1.2.5 in Script A's history and add the release note Script A: header to V1.2.5 / 2026-10-21; entries for blanton_ber_debug.sh, retimer_lanes.sh, unused_lanes.sh, the PMON power readback, the --force on the USB stress, the boot cycle title and the fast boot cycle, with notes on p=p31 vs blanton_ber.sh's p=3, the missing port 268, the double read in Script 4, the exec bits and the EN_Cold_Warm_boot = 0 hang. CLAUDE.md / ARCHITECTURE.md: status and release to V1.2.5, the new scripts in the overview, the tree and the commands. Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_0131orciRKrejchsuDk6UpXk --- ARCHITECTURE.md | 10 +++- CLAUDE.md | 22 ++++++- docs/release-notes/v1.2.5.md | 56 ++++++++++++++++++ src/Script_ABC_Blanton/1_Blanton_Script_A.ttl | 58 ++++++++++++++++++- 4 files changed, 139 insertions(+), 7 deletions(-) create mode 100644 docs/release-notes/v1.2.5.md diff --git a/ARCHITECTURE.md b/ARCHITECTURE.md index 69634bd..48603c2 100644 --- a/ARCHITECTURE.md +++ b/ARCHITECTURE.md @@ -162,6 +162,7 @@ Blanton_TTL_Script/ │ ├── 4_Blanton_Script_thermal_safety.ttl # 熱 / 安規:獨立跑,不接 A→B→C ├── 5_Blanton_Script_Boot_Cycle.ttl # 開機循環(warm / cold,EN_Cold_Warm_boot):獨立跑,while 1 無止境 + ├── 5_1_Blanton_Script_Boot_Cycle_Fast.ttl # 同 Script 5,但 Check Pt8 只跑 traffic ps(不打流量),循環較短 ├── 6_Blanton_Script_BER_Cycle.ttl # Diag ↔ SONiC 冷開機循環,兩邊各量一次 unit 0 BER:獨立跑,while 1 ├── config.ttl # 全域設定:testcase 名、EN_Margin / EN_TX_FIR / EN_log / EN_timestamp、 │ # 風扇與 SWB 宣告、SSD/USB/BMC_USB 壓力秒數、三個 prompt 字串 @@ -205,6 +206,7 @@ Blanton_TTL_Script/ │ # ⚠️ V1.1.9 起 A/B/C 內註解掉的呼叫已整段刪除,只剩手動執行 ├── blanton_ber.sh # 全機 SerDes BER 掃描(phydiag prbs / prbsstat) │ # V1.2.2 起含 port 268(100G ce0),summary 每 unit 分 200G/100G/TOTAL + ├── blanton_ber_debug.sh # BER 原始輸出(p=p31、sleep 40、-u 0|1),不判定 ├── bcm_100g_dsc_cycle.sh # 100G link down/up 循環 + 每輪 DSC 與 retimer TX/RX 讀回(未驗證) ├── bcm_dsc_scan.sh # 全機 SerDes DSC dump(phydiag dsc,~445 port × 2 unit) │ # 由 EN_TX_FIR 控制,A 與 C 各掃一次;單次約 10 分鐘 @@ -216,11 +218,13 @@ Blanton_TTL_Script/ ├── blanton_tr518.sh # TR518 封包測試,量功耗前的負載來源 ├── TH6_SWB0_power_readback.sh # SWB0 19 條軌 V×I + 總功耗 ├── TH6_SWB1_power_readback.sh # SWB1 同上 - │ # ⚠️ 已納入交付,但 A/B/C 的呼叫仍註解掉(bring-up 中) + │ # V1.2.5 起由 utils/setup_pmon.ttl 呼叫,每個 PMON 快照都有 ├── ddr5_temp.sh # DDR5 DIMM 溫度(SPD5118 @ i2c-5 0x50/0x51,reg 0x31) ├── hsc_temp_readback.sh # LTC4287 HSC 溫度(i2c-28 0x40/0x45,內/外部感溫) ├── avt_pmpower.sh # AMD CPU 封裝功耗(AVTCMD pmm get_pmdata;AVT 是 NDA,不隨包) ├── tray_id_stress.sh # Tray ID I2C stress(bus 34/35/38/39 0x70 reg 0x02,寫 0xA5/0x5A 讀回) + ├── retimer_lanes.sh # 單顆 Agera3 retimer 的 lane TX off/on/status(sys + line side) + ├── unused_lanes.sh # 依內建表把沒接線的 retimer lane / TH6 port 關掉(呼叫 retimer_lanes.sh) ├── usb_target.sh # 偵測 USB 裝置節點/掛載點(排除系統碟) ├── bmc_monitor.sh # BMC 監控:free -m + I2C 寫入/讀回圖樣測試 ├── bmc_monitor_ddr.sh # ⚠️ 已停用:V1.1.9 起 B/C 內的註解區塊已刪除,DDR 壓力走 bgctl + bmc-manager @@ -383,7 +387,7 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc | 模組 | 進入點 | 功能 | |------|--------|------| -| **Script A(Pre-test)** | `1_Blanton_Script_A.ttl` V1.2.4 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**(`hw-test-session finish` → `bgctl reset --yes` → `bgctl stop --all` → `bgctl list` 確認清空)→ `hw-test-session start` → **設定風扇轉速** → **等資料面就緒**(`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary` → `lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → **NFC 基線**(start → 30s → stop → report)→ 100G uplink 設定與狀態 → **BER 基線掃描**(依 `SWB_UNIT`,V1.2.1 新增)→ **一輪流量基線** → **SerDes DSC 基線**(`EN_TX_FIR`)→ `show uptime` | +| **Script A(Pre-test)** | `1_Blanton_Script_A.ttl` V1.2.5 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**(`hw-test-session finish` → `bgctl reset --yes` → `bgctl stop --all` → `bgctl list` 確認清空)→ `hw-test-session start` → **設定風扇轉速** → **等資料面就緒**(`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary` → `lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → **NFC 基線**(start → 30s → stop → report)→ 100G uplink 設定與狀態 → **BER 基線掃描**(依 `SWB_UNIT`,V1.2.1 新增)→ **一輪流量基線** → **SerDes DSC 基線**(`EN_TX_FIR`)→ `show uptime` | | **Script B(Stress)** | `2_Blanton_Script_B.ttl` | **V1.1.8 起 `mlucas-avx2 -cpu 0:15` 由 `systemd-run --unit=mlucas-amm`(`Type=exec`、`Restart=always`)啟動,不再是 shell 的 `&` 背景 job** + `bgctl run` 的 `memtester` / SSD / USB 壓力(v1.1.7 起 SSD/USB 的 `--runtime`/`--passes` 讀 `config.ttl` 的 `SSD_RUNTIME`/`SSD_COUNT`、`USB_RUNTIME`/`USB_COUNT`;BMC memtester 不帶次數 = 跑到被停) + BMC DDR(`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 `BMC_USB_RUNTIME` 秒的 ping,V1.1.8 前寫死 4 小時)→ 啟動 mgmt ping 監控 → **啟動 NFC 輪詢** → `jobs` / `systemctl is-active mlucas-amm` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪 PMON + `bgctl list`/`jobs`/`systemctl is-active mlucas-amm` + `sleep 60`(**V1.1.4 起 margin 不在迴圈內**;V1.2.0 起等待走 DUT 端 `sleep` 而非 macro 端 `pause`)| | **Script C(Post-test)** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + **`systemctl stop mlucas-amm`**(systemd unit 不是 shell job,`jobs -p` 抓不到)+ `bgctl stop --all` / `reset` + 停 BMC USB unit、mgmt ping 與 **NFC 輪詢** → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl` **寫進 `log/bmc_usb_net.log`**(不再印在 console) → `ip -s link show eth0/eth1` → `cat` mlucas log(並 `cp` 進 job 目錄一起帶走)→ **NFC `report`** → traffic `stop` + `report` → **SerDes DSC 收尾**(`EN_TX_FIR`)→ **BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` → **margin 掃描**(`EN_Margin`,V1.1.4 由 Script B 移來)→ `uptime` → **job log 複製到 USB(帶時戳)** → `exit` + wait『Script done』→ `hw-test-session finish` | | **Script 4(Thermal / Safety)** | `4_Blanton_Script_thermal_safety.ttl` | **獨立腳本,不接 A→B→C。** Script A 式的環境建立(登入 / session / 風扇 / `wait_init` / DUT 清單 / BMC / PCIe 清除 / `pcie_bus` / PMON / dmesg)→ **滿載**(`mlucas-avx2 -cpu 0:15`,V1.1.8 起與 Script B 同樣掛成 `mlucas-amm` systemd unit + `blanton_tr518.sh start`)→ `while 1`:PMON + `TH6_SWB0/1_power_readback.sh` + `avt_pmpower.sh`(CPU 封裝功耗,V1.2.3)+ `bgctl list` / `jobs` / `systemctl is-active mlucas-amm`,`pause 60`。**沒有收尾段** —— 中斷後 DUT 仍在 `port cd lb=mac` / `l2 learn off` / `test mode nr=yes`,且 CPU 仍滿載,要手動 `blanton_tr518.sh stop` + `systemctl stop mlucas-amm` | @@ -814,7 +818,7 @@ margin status、全部 VRM 軌的 Vin/Vout/Iout/Temp、CB + ICB 溫感讀值, - [ ] `CHANGELOG.md`:延續三支腳本頂端的 Version History,集中成一份 - [ ] 三支腳本的 header 版號與 `CHANGELOG.md` 對齊,`config.ttl` 加 `script_version` 並寫進 log 開頭 - [ ] `docs/TTL_Script_Blanton_Status_*.xlsx` 更新為全 OK,或把剩餘項目移進 Future Extensions -- [x] 打 git tag,push `nas` + `gitea`(已至 `V1.2.4`;`publish/` 依 Script A 檔頭版號打包) +- [x] 打 git tag,push `nas` + `gitea`(已至 `V1.2.5`;`publish/` 依 Script A 檔頭版號打包) **驗收條件:** 從 zip 解壓到一台乾淨的測試 NB,照 README 操作,不看原始碼就能完成一輪 A→B→C 並產出 summary;`publish/` 內容與 git tag 一致。 diff --git a/CLAUDE.md b/CLAUDE.md index 6d9a707..b0e2c19 100644 --- a/CLAUDE.md +++ b/CLAUDE.md @@ -9,7 +9,7 @@ DUT 端的取數能力由一組 **bash 工具庫** 提供(CB FPGA `pcimem` → 完整架構見 [ARCHITECTURE.md](ARCHITECTURE.md)。 -**目前狀態(2026-10-01)**:Script A 為 **V1.2.4**(A 集中記錄所有 TTL 的變更)。涵蓋 +**目前狀態(2026-10-21)**:Script A 為 **V1.2.5**(A 集中記錄所有 TTL 的變更)。涵蓋 PCIe AER / DDR EDAC / PMON+TPM / 電壓 margin(9 顆 LTC2980)/ SWB loopback 線速流量 / 10G+1G 管理網路 ping / BMC DDR 與 USB / NVMe 健康,壓力層走平台的 `bgctl`。 switch unit 數量由 `config.ttl` 的 `SWB_UNIT0` / `SWB_UNIT1` 宣告,風扇轉速由 `FAN_SPEED` 指定 @@ -39,11 +39,15 @@ NFC tag 讀取由 `nfc_polling.sh` 背景輪詢(A 做基線、B 起、C 停並 **V1.2.4 新增 Tray ID I2C stress(`tray_id_stress.sh`)**:Script A 跑一次當基線、Script B 每輪 soak 跑一次。 另新增 **`6_Blanton_Script_BER_Cycle.ttl`**(Diag ↔ SONiC 冷開機循環量 BER,**獨立跑不接 A→B→C**), 操作與分析見 `tmp/BER_Test_Cycle/runbook.md`(tmp 不進 git)。 +**V1.2.5 起 PMON 快照也帶兩片 SWB 的軌功耗**(`TH6_SWB{0,1}_power_readback.sh` 搬進 `setup_pmon.ttl`), +⚠️ Script 4 迴圈原本就自己讀一次,現在**每輪讀兩次**。V1.2.5 另有 `blanton_ber_debug.sh`(BER 原始輸出、`p=p31`、`sleep 40`)、 +`retimer_lanes.sh` / `unused_lanes.sh`(把沒接線的 retimer lane / TH6 port 關 TX),以及 +`5_1_Blanton_Script_Boot_Cycle_Fast.ttl`(Script 5 拿掉流量那段,只留 `ps`)。 以及 **`5_Blanton_Script_Boot_Cycle.ttl`**(重開機循環,**獨立跑不接 A→B→C**:登入 → 風扇 → Check Pt1~Pt13 → `reboot` → `wait "Booting in blind mode"`,`cnt_cycle` 每輪遞增,`while 1` 無止境, 要停就關 Tera Term 的 macro)。**尚未上機驗證**。 流程圖:`docs/Blanton_Test_Flow.drawio`。 -最後一次發布是 **V1.2.4**;SWB 的 I2C 通道與位址已於 2026-08-19 上機驗證。 +最後一次發布是 **V1.2.5**;SWB 的 I2C 通道與位址已於 2026-08-19 上機驗證。 margin 的 `VNOM` 已於 2026-08-30 改為 Blanton 實測中位數(144 條軌中 86 條上調 0.8~2.5%)。 交付用 `./publish/publish.sh` 打包。 @@ -178,6 +182,20 @@ sleep 30 # 至少等一個 interval 再 rep # -u 0 / -u 1 單邊;-c 1e-9 換門檻;-F 只列失敗;-f 離線重解 # ⚠️ 不能跟 blanton_traffic_linespeed / blanton_tr518 同時跑(都會接管同一批 port) +# ── BER 原始輸出(V1.2.5,不判定、不 summary,TTL 未接)── +./Blanton_Script/blanton_ber_debug.sh # unit 0+1:set p=p31 → get×2 → STArt 30 → sleep 40 → Ber → STOp → clear +./Blanton_Script/blanton_ber_debug.sh -u 0 # 單一 unit +# 清單同 tools/BER_Test.txt,不含 268;BER_PORTS="...,268" 可加 +# ⚠️ 這支是 p=p31(已上機驗證),blanton_ber.sh 仍是 p=3 —— 兩者量的碼型可能不同 + +# ── 沒接線的 retimer lane / TH6 port 關 TX(V1.2.5,TTL 未接)── +./Blanton_Script/unused_lanes.sh status # 兩 unit 全部列出 rx_lock / tx_off +./Blanton_Script/unused_lanes.sh off [--asic 0] [--th6] # 預設 TX squelch;--th6 連 retimer 後面的 TH6 port 一起關 +./Blanton_Script/unused_lanes.sh on +./Blanton_Script/retimer_lanes.sh 0 0x102 0xff status # 單顆 retimer: +# ⚠️ lane 有 RX lock(有訊號進來)時 off 會被拒絕(exit 2),--force 才會硬關 +# ⚠️ unused_lanes.sh 會檢查同目錄的 retimer_lanes.sh 有沒有 exec bit —— 兩支都要 chmod +x + # ── SerDes DSC 擷取(TX_FIR / RXFFE / DFE / EYE / SNR)── ./Blanton_Script/bcm_dsc_scan.sh # unit 0+1 全掃,約 10 分鐘 ./Blanton_Script/bcm_dsc_scan.sh -u 0 # 只掃一個 unit(時間減半) diff --git a/docs/release-notes/v1.2.5.md b/docs/release-notes/v1.2.5.md new file mode 100644 index 0000000..ccf08f9 --- /dev/null +++ b/docs/release-notes/v1.2.5.md @@ -0,0 +1,56 @@ +# v1.2.5 — Switch-board rail power in every snapshot, a raw BER run, and tools to turn off unused lanes + +## ✨ New features + +**PMON snapshots now carry the switch-board rail power** +* `utils/setup_pmon.ttl` calls `TH6_SWB0_power_readback.sh` and `TH6_SWB1_power_readback.sh` right after `show platform current` — the 19 rails of each switch board with V × I and a `TOTAL POWER` line. +* `setup_pmon` is shared, so this lands in Script A, B, C, 4 and 5 alike. + +**`blanton_ber_debug.sh` — the hand-run BER flow as one command** +* Runs exactly what `tools/BER_Test.txt` does: `prbs set p=p31` → `prbs get` twice → `prbsstat STArt Interval=30` → `sleep 40` → `prbsstat Ber` → `STOp` → `prbs clear`. +* Every `bcmcmd` output is printed **as is**, under a `### [time] unit N: ...` header — no parsing, no PASS/FAIL, no summary. For looking at the raw output on the bench; `blanton_ber.sh` remains the judged version. +* `-u 0` / `-u 1` for one switch unit; both by default. `BER_POLY`, `BER_INTERVAL`, `BER_WAIT` and `BER_PORTS` can be overridden from the environment. + +**`retimer_lanes.sh` / `unused_lanes.sh` — turn off TX on lanes nothing is cabled to** +* `retimer_lanes.sh ` acts on one Agera3 retimer, sys **and** line side. `--method squelch` (default, TX squelch, lanes stay powered) or `--method power` (TX+RX power-down, needs an `agera3` that has the `power` command). It reads the state back afterwards and prints `PASS` / `FAIL`. +* `unused_lanes.sh ` applies that to a built-in table — 14 retimer rows and one direct-TH6 row (TSC31, `cd112-cd115`) — on both switch boards. `--asic 0|1|all`, `--th6` to also disable the TH6 ports behind the retimer rows, `--only ` for a single row. Ends with `ok / refused / failed` counts. +* **`off` is refused on a lane that receives a signal** (RX PMD lock, or link up on a TH6 port) unless `--force` is given. + +**`5_1_Blanton_Script_Boot_Cycle_Fast.ttl` — the boot cycle without the traffic run (standalone)** +* Identical to Script 5, except Check Pt8 only runs `blanton_traffic_linespeed ps` — no `init` / `start` / 15 s / `stop` / `report`. A shorter cycle when the point is the number of boots. + +**Boot cycle shows its count in the window title** +* Script 5 and 5_1 set the Tera Term title to `Reboot Cycle Test : n` or `Power Cycle Test : n` each round. + +## 🐛 Bug fixes + +**`qfx5252-stress-usb` now runs with `--force`** in Script B and in the boot cycles. + +## 📦 Downloads + +| File | Contents | +|---|---| +| `Script_ABC_Blanton_V1.2.5.zip` | The full Tera Term working directory, including `Blanton_Script/` to copy onto the DUT | + +```bash +chmod +x ~/Blanton_Script/*.sh +grep -rlU $'\r' ~/Blanton_Script # expect no output +``` + +## ⚠️ Before you run + +* **`chmod +x` after deploying.** The power readbacks are called by path from every PMON snapshot, and `unused_lanes.sh` refuses to start unless `retimer_lanes.sh` next to it is executable. +* **Script 4 now reads the switch-board power twice per round** — once inside `setup_pmon`, once from its own loop. Harmless, but the log carries both. +* **`blanton_ber_debug.sh` uses `p=p31` (verified on the bench); `blanton_ber.sh`, and so Script A / C, still sets `p=3`.** The two may not be measuring the same pattern — do not compare their BER directly until that is settled. +* **`blanton_ber_debug.sh` leaves out port 268**, the same list as `BER_Test.txt`. Add it with `BER_PORTS="...,268"`. +* **`EN_Cold_Warm_boot = 0` (the `config.ttl` default) hangs Script 5 and 5_1.** Set it to `1` (reboot) or `2` (power cycle). +* **Script 5 and 5_1 are two copies of the same macro** — a fix to one has to be made to the other. +* **Script 4 has no teardown**: finish it with `blanton_tr518.sh stop` **and** `systemctl stop mlucas-amm`. +* **`FAN_SPEED` is 100.** + +## 🔗 Links + +* [ARCHITECTURE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/ARCHITECTURE.md) — test flow, data models, constraints +* [CLAUDE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/CLAUDE.md) — commands and the bench gotchas + +**Full changelog:** [V1.2.4...V1.2.5](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/compare/V1.2.4...V1.2.5) diff --git a/src/Script_ABC_Blanton/1_Blanton_Script_A.ttl b/src/Script_ABC_Blanton/1_Blanton_Script_A.ttl index 7a7a972..bf6be20 100644 --- a/src/Script_ABC_Blanton/1_Blanton_Script_A.ttl +++ b/src/Script_ABC_Blanton/1_Blanton_Script_A.ttl @@ -1,7 +1,7 @@ ; ============================================================================= ; Script A for Blanton -; Version : V1.2.4 -; Date : 2026-10-01 +; Version : V1.2.5 +; Date : 2026-10-21 ; Author : ETWen ; ============================================================================= ; Version History: @@ -794,6 +794,60 @@ ; Diag vs SONiC comparison ; !! measures unit 0 only, port 268 not in the list, yet ; wait_init still waits for BOTH units (SWB_UNIT0/1 = 1) +; V1.2.5 2026-10-21 Blanton_Script/blanton_ber_debug.sh Created v1.0.0 - raw BER run of tools/BER_Test.txt +; prbs set p=p31, prbs get x2, prbsstat STArt Interval=30, +; sleep 40, Ber, STOp, prbs clear. Every bcmcmd output is +; printed as is under a '### [time] unit N: ...' header - no +; parsing, no PASS/FAIL, no summary. -u 0 / -u 1, default both +; BER_POLY / BER_INTERVAL / BER_WAIT / BER_PORTS overridable +; !! the port list is the 200G ports only, no 268 - same as +; BER_Test.txt. BER_PORTS="...,268" adds the 100G uplink +; !! p=p31 is verified on the bench. blanton_ber.sh (and so +; Script A / C) still sets p=3 - the two runs do not measure +; the same pattern unless p=3 is PRBS31 as well +; !! standalone, no TTL calls it +; Blanton_Script/retimer_lanes.sh Created - TX off / on / status for lanes of one Agera3 retimer +; retimer_lanes.sh +; Acts on the sys AND the line side. --method squelch (default, +; TX squelch, lanes stay powered) or power (TX+RX power-down, +; needs an agera3 with the 'power' command - exit 4 if not) +; Reads back after the change: PASS / FAIL, exit 3 on mismatch +; !! 'off' is REFUSED (exit 2) on a lane with RX PMD lock, i.e. +; one that receives a signal. --force overrides +; !! runs agera3 through sudo, 30 s timeout per call +; Blanton_Script/unused_lanes.sh Created - apply off / on / status to every unused lane +; Table at the top: 14 retimer rows (7 fully unused, 7 with +; lanes 4,5 unused) and 1 direct-TH6 row (TSC31, cd112-cd115), +; the same rows on both switch boards. Retimer rows go through +; retimer_lanes.sh, TH6 rows through 'port ... enable=' in +; syncdN's bcmcmd. --asic 0|1|all; --th6 also turns off the TH6 +; ports behind the retimer rows; --only for one row +; Ends with ok / refused / failed counts, exit 1 if any failed +; !! calls retimer_lanes.sh from its own directory and checks +; its exec bit - chmod +x both after deploying +; !! bash only (mapfile, [[ =~ ]]), not sh +; utils/setup_pmon.ttl Add TH6_SWB0 / TH6_SWB1 power readback after show platform current +; Every PMON snapshot (A / B / C / 4 / 5) now has the 19 rails +; of each switch board with V x I and TOTAL POWER +; !! Script 4 already called both readbacks in its loop right +; after setup_pmon - it now reads them TWICE per round +; !! every Script B soak round gets longer by both readbacks +; ScriptB Add --force to qfx5252-stress-usb +; 5_.._Boot_Cycle.ttl Window title shows the cycle count every round +; 'Reboot Cycle Test : n' (EN_Cold_Warm_boot = 1) or +; 'Power Cycle Test : n' (= 2), set with settitle +; Add --force to qfx5252-stress-usb, same as Script B +; 5_1_Blanton_Script_Boot_Cycle_Fast.ttl Added - Script 5 without the traffic run, a STANDALONE macro +; Identical to 5_.._Boot_Cycle.ttl except that Check Pt8 runs +; only 'blanton_traffic_linespeed ps' - no init / clear / show +; / start / pause 15 / stop / report. A shorter cycle when the +; point is the number of boots +; !! a second copy of the same macro: a fix to one has to be +; made to the other as well +; !! EN_Cold_Warm_boot = 0 (the config.ttl default) hangs it, +; same as Script 5 +; tools/BER_Test.txt p=3 -> p=p31; add a unit 1 block, a both-units block and +; port en=0 / en=1 for all cabled ports on each unit ; ============================================================================= include "config.ttl"