docs: Update CLAUDE / ARCHITECTURE for V1.2.0 and add the release note
CLAUDE.md: status to V1.2.0 / 2026-09-07; the PRBS paragraph now says the A/B/C call sites were deleted in V1.1.9 rather than commented out; the DSC scan and parser get a commands block and a line in the status summary; the soak loop uses sleep 60; the bcmcmd gotcha records that bcm_dsc_scan.sh hit the same stdin trap on 2026-09-07 and why the existing marker check could not see it; and a new gotcha on pause versus sleep. ARCHITECTURE.md: bcm_dsc_scan.sh / bcm_dsc_parse.sh in the tree and a Key Features row of their own; EN_TX_FIR in the config.ttl line; Script A ref to V1.2.0 and the A / B / C rows updated for the DSC steps and sleep; constraint 10 extended with the recurrence; new constraint 18 (pause stops the macro, sleep stops the DUT) with the old 18 renumbered to 19 and EN_TX_FIR added to it; the git tag checkbox to V1.2.0; the PRBS and bmc_monitor_ddr known issues corrected from "commented out" to "deleted"; and a new known issue for the DSC scan being off by default and sharing ports with the other traffic tools. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_014RetWKFZFG1ZHcitQAyhwM
This commit is contained in:
+36
-14
@@ -161,7 +161,7 @@ Blanton_TTL_Script/
|
||||
│
|
||||
├── 4_Blanton_Script_thermal_safety.ttl # 熱 / 安規:獨立跑,不接 A→B→C
|
||||
├── 5_Blanton_Script_Reboot_Cycle.ttl # 重開機循環:獨立跑,while 1 無止境(未上機驗證)
|
||||
├── config.ttl # 全域設定:testcase 名、EN_Margin / EN_log / EN_timestamp、
|
||||
├── config.ttl # 全域設定:testcase 名、EN_Margin / EN_TX_FIR / EN_log / EN_timestamp、
|
||||
│ # 風扇與 SWB 宣告、SSD/USB/BMC_USB 壓力秒數、三個 prompt 字串
|
||||
├── hammer/ # 🚫 gitignored — mlucas ELF binary(~99 MB),DUT image 自帶,
|
||||
│ # publish.sh 也排除;Script B / Script 4 只負責 chmod +x 後執行
|
||||
@@ -199,7 +199,11 @@ Blanton_TTL_Script/
|
||||
├── mgmt_ping_monitor.sh # 10G/1G 管理網路 ping 監控(iproute2)
|
||||
│ # eth0→TARGET_10G、eth1→TARGET_1G,兩張卡同時持續 ping
|
||||
├── port_prbs_monitor.sh # 100G uplink PRBS 測試(bcmcmd phy diag)
|
||||
│ # ⚠️ V1.1.9 起 A/B/C 內註解掉的呼叫已整段刪除,只剩手動執行
|
||||
├── blanton_ber.sh # 全機 SerDes BER 掃描(phydiag prbs / prbsstat)
|
||||
├── bcm_dsc_scan.sh # 全機 SerDes DSC dump(phydiag <port> dsc,~445 port × 2 unit)
|
||||
│ # 由 EN_TX_FIR 控制,A 與 C 各掃一次;單次約 10 分鐘
|
||||
├── bcm_dsc_parse.sh # DSC raw log → <prefix>_lane.csv / _pm.csv(純 sh + awk)
|
||||
├── blanton_multiphase_margin.sh # 多相 VRM margin(原生 i2c,38 條軌)
|
||||
├── pwr_brick.sh # PDB / CPB power brick 讀值(VI2C ch4)
|
||||
├── nfc_polling.sh # NFC tag 背景輪詢 + PASS/FAIL 統計
|
||||
@@ -210,7 +214,7 @@ Blanton_TTL_Script/
|
||||
│ # ⚠️ 已納入交付,但 A/B/C 的呼叫仍註解掉(bring-up 中)
|
||||
├── usb_target.sh # 偵測 USB 裝置節點/掛載點(排除系統碟)
|
||||
├── bmc_monitor.sh # BMC 監控:free -m + I2C 寫入/讀回圖樣測試
|
||||
├── bmc_monitor_ddr.sh # ⚠️ 已停用:B/C 內呼叫處已註解,DDR 壓力改走 bgctl + bmc-manager
|
||||
├── bmc_monitor_ddr.sh # ⚠️ 已停用:V1.1.9 起 B/C 內的註解區塊已刪除,DDR 壓力走 bgctl + bmc-manager
|
||||
│ # ↑ 三支都要 chmod +x 才能跑(見 Key Constraints)
|
||||
└── LTC2980_Margin_Script/ # 電壓 margin 子專案(另有獨立 repo)
|
||||
├── margin.sh # margin_init/status/set/apply_profile/save
|
||||
@@ -370,9 +374,9 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc
|
||||
|
||||
| 模組 | 進入點 | 功能 |
|
||||
|------|--------|------|
|
||||
| **Script A(Pre-test)** | `1_Blanton_Script_A.ttl` V1.1.8 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**(`hw-test-session finish` → `bgctl reset --yes` → `bgctl stop --all` → `bgctl list` 確認清空)→ `hw-test-session start` → **設定風扇轉速** → **等資料面就緒**(`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary` → `lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → **NFC 基線**(start → 30s → stop → report)→ 100G uplink 設定與狀態 → **一輪流量基線** → `show uptime` |
|
||||
| **Script B(Stress)** | `2_Blanton_Script_B.ttl` | **V1.1.8 起 `mlucas-avx2 -cpu 0:15` 由 `systemd-run --unit=mlucas-amm`(`Type=exec`、`Restart=always`)啟動,不再是 shell 的 `&` 背景 job** + `bgctl run` 的 `memtester` / SSD / USB 壓力(v1.1.7 起 SSD/USB 的 `--runtime`/`--passes` 讀 `config.ttl` 的 `SSD_RUNTIME`/`SSD_COUNT`、`USB_RUNTIME`/`USB_COUNT`;BMC memtester 不帶次數 = 跑到被停) + BMC DDR(`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 `BMC_USB_RUNTIME` 秒的 ping,V1.1.8 前寫死 4 小時)→ 啟動 mgmt ping 監控 → **啟動 NFC 輪詢** → `jobs` / `systemctl is-active mlucas-amm` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪 PMON + `bgctl list`/`jobs`/`systemctl is-active mlucas-amm` + `pause 60`(**V1.1.4 起 margin 不在迴圈內**)|
|
||||
| **Script C(Post-test)** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + **`systemctl stop mlucas-amm`**(systemd unit 不是 shell job,`jobs -p` 抓不到)+ `bgctl stop --all` / `reset` + 停 BMC USB unit、mgmt ping 與 **NFC 輪詢** → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl` **寫進 `log/bmc_usb_net.log`**(不再印在 console) → `ip -s link show eth0/eth1` → `cat` mlucas log(並 `cp` 進 job 目錄一起帶走)→ **NFC `report`** → traffic `stop` + `report` → **BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` → **margin 掃描**(`EN_Margin`,V1.1.4 由 Script B 移來)→ `uptime` → **job log 複製到 USB(帶時戳)** → `exit` + wait『Script done』→ `hw-test-session finish` |
|
||||
| **Script A(Pre-test)** | `1_Blanton_Script_A.ttl` V1.2.0 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**(`hw-test-session finish` → `bgctl reset --yes` → `bgctl stop --all` → `bgctl list` 確認清空)→ `hw-test-session start` → **設定風扇轉速** → **等資料面就緒**(`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary` → `lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → **NFC 基線**(start → 30s → stop → report)→ 100G uplink 設定與狀態 → **一輪流量基線** → **SerDes DSC 基線**(`EN_TX_FIR`)→ `show uptime` |
|
||||
| **Script B(Stress)** | `2_Blanton_Script_B.ttl` | **V1.1.8 起 `mlucas-avx2 -cpu 0:15` 由 `systemd-run --unit=mlucas-amm`(`Type=exec`、`Restart=always`)啟動,不再是 shell 的 `&` 背景 job** + `bgctl run` 的 `memtester` / SSD / USB 壓力(v1.1.7 起 SSD/USB 的 `--runtime`/`--passes` 讀 `config.ttl` 的 `SSD_RUNTIME`/`SSD_COUNT`、`USB_RUNTIME`/`USB_COUNT`;BMC memtester 不帶次數 = 跑到被停) + BMC DDR(`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 `BMC_USB_RUNTIME` 秒的 ping,V1.1.8 前寫死 4 小時)→ 啟動 mgmt ping 監控 → **啟動 NFC 輪詢** → `jobs` / `systemctl is-active mlucas-amm` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪 PMON + `bgctl list`/`jobs`/`systemctl is-active mlucas-amm` + `sleep 60`(**V1.1.4 起 margin 不在迴圈內**;V1.2.0 起等待走 DUT 端 `sleep` 而非 macro 端 `pause`)|
|
||||
| **Script C(Post-test)** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + **`systemctl stop mlucas-amm`**(systemd unit 不是 shell job,`jobs -p` 抓不到)+ `bgctl stop --all` / `reset` + 停 BMC USB unit、mgmt ping 與 **NFC 輪詢** → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl` **寫進 `log/bmc_usb_net.log`**(不再印在 console) → `ip -s link show eth0/eth1` → `cat` mlucas log(並 `cp` 進 job 目錄一起帶走)→ **NFC `report`** → traffic `stop` + `report` → **SerDes DSC 收尾**(`EN_TX_FIR`)→ **BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` → **margin 掃描**(`EN_Margin`,V1.1.4 由 Script B 移來)→ `uptime` → **job log 複製到 USB(帶時戳)** → `exit` + wait『Script done』→ `hw-test-session finish` |
|
||||
| **Script 4(Thermal / Safety)** | `4_Blanton_Script_thermal_safety.ttl` | **獨立腳本,不接 A→B→C。** Script A 式的環境建立(登入 / session / 風扇 / `wait_init` / DUT 清單 / BMC / PCIe 清除 / `pcie_bus` / PMON / dmesg)→ **滿載**(`mlucas-avx2 -cpu 0:15`,V1.1.8 起與 Script B 同樣掛成 `mlucas-amm` systemd unit + `blanton_tr518.sh start`)→ `while 1`:PMON + `TH6_SWB0/1_power_readback.sh` + `bgctl list` / `jobs` / `systemctl is-active mlucas-amm`,`pause 60`。**沒有收尾段** —— 中斷後 DUT 仍在 `port cd lb=mac` / `l2 learn off` / `test mode nr=yes`,且 CPU 仍滿載,要手動 `blanton_tr518.sh stop` + `systemctl stop mlucas-amm` |
|
||||
| **Script 5(Reboot Cycle)** | `5_Blanton_Script_Reboot_Cycle.ttl` | **獨立腳本,不接 A→B→C。** `while 1`:登入 → `sudo -i` → 對時 → 風扇 → **Check Pt1~Pt13**(DUT/BMC info、mgmt ping、NFC、SSD、USB、BMC USB、port status + 15s traffic、BER、NVMe、platform data、dmesg i2c、PCIe error counters)→ `show uptime` → `reboot` → `wait "Booting in blind mode"`。`cnt_cycle` 每輪 +1 印在標頭。**沒有結束條件** —— 要停就關掉 Tera Term 的 macro。**尚未上機驗證** |
|
||||
| **SWB loopback 流量** | `blanton_traffic_linespeed <sub> [-u 0\|1\|all]` | `init`(VLAN 30..137,成對 `cdN`/`cdN+32`)→ `clear` → `start`(`tx 200 length=324 PatternRandom=yes`,v0.7.0 起)→ `stop` → `report`(per-pair TX/RX 交叉比對 PASS/FAIL);另有 `ps`(link/speed)與 `run`(一條龍)。**V0.6.0 起含 100G uplink `ce0`**(VLAN 138):它沒有 loopback 對象,靠 **ingress mirror 打回自己**維持循環,`report` 最後一列就是它,底下再接一份跨 unit summary |
|
||||
@@ -386,8 +390,9 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc
|
||||
| **Margin 寫 NVM** | `margin_save` / `margin_save all` / `margin_save blanton` | ⚠️ 永久寫入。`0x15` 送 PMBus **send-byte**(不帶 data byte)。`all` = 依 `settings/` 走 9 顆、跑完還原原本載入的板子;`blanton` = 本平台捷徑,18 顆全走原生 i2c bus(`MARGIN_BLANTON_STORE` 表),不需 `margin_init`。每筆之間 `MARGIN_STORE_SETTLE`(0.5s),工具**不 poll busy bit** |
|
||||
| **管理網路 ping** | `mgmt_ping_monitor.sh {start\|stop\|status\|fg\|tail\|clear\|summary}` | 一輪 = 10G leg + 1G leg,各自 `ip address/route replace` 後 `ping -I <if>` 打自己的對端;兩張卡都保持 up。每 leg 記 `ip -s link show` 與該卡的 TX/RX packet delta,另出一行可 grep 的 `RESULT` |
|
||||
| **BMC 監控** | `bmc_monitor.sh {start\|stop\|status\|fg\|tail\|clear}` | 由 host 端 `bmc-manager run` 週期取樣 `free -m`,另加一組 **I2C 寫入/讀回圖樣測試**(bus 1、addr 0x41、offset 0x00C0,寫 `55AA55AA` 讀回、再寫 `AA55AA55` 讀回)。B 啟動、C 停止並 `cat log/bmc_poll.log` |
|
||||
| **BMC DDR 壓力** | `bmc_monitor_ddr.sh` | ⚠️ **已停用** —— B/C 內呼叫處已註解,改由 `bgctl run bmc-manager run memtester` 取代。檔案保留未刪 |
|
||||
| **100G PRBS** | `port_prbs_monitor.sh {start [both\|a\|b]\|stop\|status\|report\|clear}` | 兩個 uplink 各一個 worker,可同時或單獨跑。setup(`lpmode off` → `prbs set` → `prbsstat STArt`)→ 週期 `prbs get`(判定)+ `prbsstat Ber`(只記錄)→ teardown(`STOp` + `prbs clear`)。輸出含 `PRBS OK!` 才算 PASS。**⚠️ A/B/C 的呼叫目前註解掉** |
|
||||
| **BMC DDR 壓力** | `bmc_monitor_ddr.sh` | ⚠️ **已停用** —— V1.1.9 起 B/C 內的註解區塊已刪除,改由 `bgctl run bmc-manager run memtester` 取代。檔案保留未刪 |
|
||||
| **SerDes DSC 擷取** | `bcm_dsc_scan.sh [-u 0\|1] [-f <name>] [-F] [-n] [-C]` + `bcm_dsc_parse.sh -i <log> -o <prefix>` | `bcmcmd -n <unit> -c "dsh -c 'phydiag <port> dsc'"` 掃全清單(1 個 100G + 445 個 200G port)× 2 unit,raw log 寫進 `<script_dir>/log` 再 `cp` 到 `/host/hw-eval/jobs`。`-f` 支援 `%u` / `%t`;沒帶 `%u` 時自動插 `_u0`/`_u1`。成功與否**不看 `bcmcmd` 的 exit code**,改比對 `SERDES DISPLAY DIAG DATA END` 數量 + 實際迭代筆數,結尾印 `### DSC_SCAN_DONE rc=<n>`。parse 端輸出 `_lane.csv`(每 lane:TXEQ/RXFFE/DFE/EYE/SNR)與 `_pm.csv`(每 pm_id:溫度/PLL/lane 數/統計)。**由 `EN_TX_FIR` 控制,預設關** |
|
||||
| **100G PRBS** | `port_prbs_monitor.sh {start [both\|a\|b]\|stop\|status\|report\|clear}` | 兩個 uplink 各一個 worker,可同時或單獨跑。setup(`lpmode off` → `prbs set` → `prbsstat STArt`)→ 週期 `prbs get`(判定)+ `prbsstat Ber`(只記錄)→ teardown(`STOp` + `prbs clear`)。輸出含 `PRBS OK!` 才算 PASS。**⚠️ V1.1.9 起 A/B/C 內的註解呼叫已刪除,只能手動跑** |
|
||||
| **SerDes BER 掃描** | `blanton_ber.sh {init\|clear\|start\|stop\|report} [-u 0\|1\|all]` | 全機每個對接 port 的 PRBS BER:`prbs set p=3` + `prbs get`(確認每條 lane 都鎖上)→ `prbsstat STArt Interval=30` →(等一個 interval)→ `prbsstat Ber` → `STOp` → `prbs clear`。`report` 一列一條 lane,**BER < 1e-6 才 PASS**,最後跨 unit 的 summary 帶最差 lane。⚠️ PRBS 期間 link 顯示 DOWN、不過流量 |
|
||||
| **TR518 負載** | `blanton_tr518.sh {start\|stop} [-u 0\|1\|all]` | `port cd lb=mac` → `l2 learn off` → `test mode nr=yes` → `tr 518 ... testphase=1`,然後 settle `TR_SETTLE_SEC`(120s)再讓人量功耗。`stop` 只送 `port cd lb=none`(照 `TR518.txt`),L2 學習與 test mode **不會還原**,`TR_RESTORE_*=1` 才會 |
|
||||
| **PDB / CPB brick** | `pwr_brick.sh show [-r]` | 5 顆 brick 的 Vin / Iin / Vout / Iout / Temp(SWB0 `0x62`/`0x63`、SWB1 `0x60`/`0x61`、CPB `0x26`)。四顆 ADPM12200 **每個量各自一個 PMBus PAGE**(Vin 9、Iin 10、Vout 2、Iout 14、Temp 18),讀之前一定要先寫 PAGE —— `blanton_pwr_data.sh` 完全沒寫,所以整張 PDB 表都是 NA。換算用手冊 DIRECT 公式 `X=(1/m)(Y×10⁻ᴿ−b)`。每個值重讀到通過三道檢查為止(非 `0xFFFF`、非 `0x0000`、落在合理範圍)—— 這條匯流排**只壞高位元組**,`11.98 V` 會變成 `32.00 V`,全一過濾擋不住 |
|
||||
@@ -510,6 +515,11 @@ pwr_data
|
||||
`vlan create` 的 `Entry exists`(重跑 init)與 `vlan remove` 的 `not found`(init 前先 stop)
|
||||
當良性情況分開計數。另外 `bcmcmd` 一律以 `</dev/null` 執行 ——
|
||||
否則它會吃掉 while 迴圈的 stdin,導致**只有第一個 VLAN 被設定**(V0.3.1 修的 bug)。
|
||||
**2026-09-07 `bcm_dsc_scan.sh` 又踩了同一個坑**(port 清單走 stdin,445 個 port 只掃了 1 個),
|
||||
而且因為 `### PORT` marker 與 dsc 區塊數量一起變少,原本的比對檢查完全看不出來、`rc=0`。
|
||||
修法:迴圈改讀 fd 3(`done 3< "$PORTFILE"`)+ `bcmcmd ... < /dev/null`,再加一道
|
||||
「實際迭代筆數 == 清單筆數」的獨立檢查。**寫任何餵檔案給 `while` 又在裡面呼叫 `bcmcmd` 的迴圈,
|
||||
都要假設它會讀 stdin;而且完整性檢查不能只比對兩個會一起變少的數字。**
|
||||
11. **DUT 密碼不得進 git**:`1_Blanton_Script_A.ttl` 目前的 `sendln "YourPaSsWoRd"` 是 placeholder,
|
||||
實際帳密必須放 `secret/config_secret.ttl`(gitignored)並由 `config.ttl` include。
|
||||
12. **`.sh` / `.conf` 必須是 LF**:CRLF 的 shell script 在 SONiC 上直接掛
|
||||
@@ -549,8 +559,15 @@ pwr_data
|
||||
⚠️ **`4_Blanton_Script_thermal_safety.ttl` 用同一個 `mlucas-amm` unit,但它沒有收尾段**,
|
||||
所以那行 `systemctl stop mlucas-amm` 必須由測試員手動下 —— 這是 Script 4 目前
|
||||
唯一一個「不下就會延續到下一輪」的負載。
|
||||
18. **`config.ttl` 少一個變數會讓 macro 當場中止**,不是當成 0。V1.1.8 新增 `EN_timestamp`
|
||||
(Script A `logopen` 的第 5 個參數)與 `BMC_USB_RUNTIME`(Script B 的 ping unit)。
|
||||
18. **`pause` 停的是 macro,`sleep` 停的是 DUT。** V1.2.0 起 A/B/C 的等待一律改成
|
||||
`sendln "sleep N"` + `wait prompt_sonic_root`。`pause N` 期間 macro 不理會 DUT,shell 是閒著的,
|
||||
等於用猜的估上一個指令要跑多久 —— DUT 一忙就會提早往下送指令;改成 DUT 端 `sleep` 之後,
|
||||
prompt 回來才繼續,兩邊不可能走散,而且這段等待會帶時戳進 log,事後看得出哪一輪跑久了。
|
||||
⚠️ **Script 4 與 Script 5 尚未轉換,仍在用 `pause`**;B/C 開頭的 `pause 1` 也保留
|
||||
(它在登入前執行,沒有 prompt 可等)。
|
||||
19. **`config.ttl` 少一個變數會讓 macro 當場中止**,不是當成 0。V1.1.8 新增 `EN_timestamp`
|
||||
(Script A `logopen` 的第 5 個參數)與 `BMC_USB_RUNTIME`(Script B 的 ping unit);
|
||||
V1.2.0 再加 `EN_TX_FIR`(A/C 的 DSC 掃描與 C 的四行 `cp`,預設 0)。
|
||||
只更新 `.ttl` 卻沿用舊的 `config.ttl`,Script A 會停在 `logopen` 那一行。
|
||||
另外 **時間戳的「格式」不在 macro 裡** —— 它在 Tera Term 的
|
||||
Setup → Additional settings → Log,存在那台電腦的 `TERATERM.INI`,會跟著 PC 而不是跟著腳本走。
|
||||
@@ -787,7 +804,7 @@ margin status、全部 VRM 軌的 Vin/Vout/Iout/Temp、CB + ICB 溫感讀值,
|
||||
- [ ] `CHANGELOG.md`:延續三支腳本頂端的 Version History,集中成一份
|
||||
- [ ] 三支腳本的 header 版號與 `CHANGELOG.md` 對齊,`config.ttl` 加 `script_version` 並寫進 log 開頭
|
||||
- [ ] `docs/TTL_Script_Blanton_Status_*.xlsx` 更新為全 OK,或把剩餘項目移進 Future Extensions
|
||||
- [x] 打 git tag,push `nas` + `gitea`(已至 `V1.1.8`;`publish/` 依 Script A 檔頭版號打包)
|
||||
- [x] 打 git tag,push `nas` + `gitea`(已至 `V1.2.0`;`publish/` 依 Script A 檔頭版號打包)
|
||||
|
||||
**驗收條件:** 從 zip 解壓到一台乾淨的測試 NB,照 README 操作,不看原始碼就能完成一輪 A→B→C
|
||||
並產出 summary;`publish/` 內容與 git tag 一致。
|
||||
@@ -821,14 +838,19 @@ margin status、全部 VRM 軌的 Vin/Vout/Iout/Temp、CB + ICB 溫感讀值,
|
||||
Script A 既不往下走也不報錯。可加最大重試次數 + `messagebox` 提示。
|
||||
- **腳本的執行權**:`mgmt_ping_monitor.sh` 與 `bmc_monitor.sh`(以及已停用的 `bmc_monitor_ddr.sh`)需人工 `chmod +x`。
|
||||
可在 Script B 起它之前補一行(比照既有的 `chmod +x ~/hammer/tools/amd/mlucas-avx2`),或在 publish 時處理。
|
||||
- **`bmc_monitor_ddr.sh` 已停用**:B/C 內的呼叫已註解,DDR 壓力改由 `bgctl run bmc-manager run memtester`
|
||||
取代。檔案還留在 repo,待確認不再需要後刪除,或在檔頭標註停用。
|
||||
- **`bmc_monitor_ddr.sh` 已停用**:V1.1.9 起 B/C 內那段註解掉的呼叫已刪除,DDR 壓力由
|
||||
`bgctl run bmc-manager run memtester` 取代。檔案還留在 repo,待確認不再需要後刪除,或在檔頭標註停用。
|
||||
(`bmc_monitor.sh` 已於 2026-08-25 重新啟用,並加上 I2C 寫入/讀回圖樣測試。)
|
||||
- **`rm /host/hw-eval/jobs/*` 清不掉子目錄**:Script A 用的是不帶 `-r` 的 `rm`,但 Script C
|
||||
是 `cp -r` 那個目錄,代表裡面可能有子目錄。清不乾淨的話,上一輪的 job log 會被當成這輪的一起
|
||||
複製到 USB。要確認 `bgctl` 的產出結構,必要時改成 `rm -rf .../jobs/*`。
|
||||
- **100G PRBS 尚未接進 A/B/C**:`port_prbs_monitor.sh` 已隨包交付、可手動執行,但三支腳本裡的呼叫
|
||||
都還註解著(bring-up 中)。要啟用時記得 PRBS 期間 link 會顯示 down,`stop` 之後才會回來。
|
||||
- **100G PRBS 已從 A/B/C 移除**:`port_prbs_monitor.sh` 仍隨包交付、仍可手動執行,但 V1.1.9 起
|
||||
三支腳本裡那些註解掉的呼叫已整段刪除(連同 Script C 的 `bmc_monitor_ddr.sh` 區塊)。
|
||||
要接回去得重寫,不是把註解拿掉。啟用時記得 PRBS 期間 link 會顯示 down,`stop` 之後才會回來。
|
||||
- **DSC 擷取預設是關的**:`EN_TX_FIR = 0`,所以出貨設定不會跑 `bcm_dsc_scan.sh`。
|
||||
開啟後 Script A 與 Script C 各掃一次、整輪多約 20 分鐘;只要單邊資料可以在腳本裡改成 `-u 0`。
|
||||
掃描本身是唯讀(`phydiag ... dsc` 不改 SerDes 設定),但**它與 `blanton_ber.sh` /
|
||||
`blanton_traffic_linespeed` / `blanton_tr518.sh` 一樣都在動同一批 port,不要同時跑**。
|
||||
- **Script 5(Reboot Cycle)尚未上機驗證**:`5_Blanton_Script_Reboot_Cycle.ttl` 隨 V1.1.7 交付,
|
||||
但還沒在真 DUT 上跑過一輪完整循環。兩個要現場確認的點:`wait "Booting in blind mode"` 是否
|
||||
真的在每一版開機訊息裡出現(沒出現就會永遠等下去,而且沒有 `timeout` 保護);以及每輪重跑
|
||||
|
||||
Reference in New Issue