docs(release): Add v1.0.7 notes; bump Script A header to V1.0.7
Script A carried a V1.0.7 history block while its "; Version :" header still read V1.0.6, so publish.sh built Script_ABC_Blanton_V1.0.6 and the folder would have disagreed with the tag. Header and date corrected -- reading the version from the header rather than a flag is what surfaced this. utils/wait_init.ttl V3.1.1: poll interval 10 s -> 60 s, and the WT_MIN comments now say "at least" to match the test, which has been `< WT_MIN` since the threshold was fixed. The stale "more than" wording described exactly the off-by-one that once hung Script A. Script C: the BMC USB journalctl dump is commented out. docs/release-notes/v1.0.7.md written in the house format. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_014RetWKFZFG1ZHcitQAyhwM
This commit is contained in:
@@ -0,0 +1,65 @@
|
||||
# v1.0.7 — Management-link ping test, and the fans start where you set them
|
||||
|
||||
## ✨ New features
|
||||
|
||||
**10G / 1G management port ping test**
|
||||
* New `mgmt_ping_monitor.sh` exercises both management NICs in one loop: it brings each up with iproute2, waits for the link to settle, then pings that NIC's own target — `eth0` → `192.168.1.30`, `eth1` → `192.168.1.31`.
|
||||
* Runs detached like the other monitors: `start` / `stop` / `status` / `fg` / `summary`. `start` clears the previous log, so one run means one log.
|
||||
* Every leg writes a single greppable line — `RESULT 10G eth0 -> 192.168.1.30 tx=10 rx=10 loss=0% rtt_avg=1.743ms nic_tx=10 nic_rx=10 PASS` — so a whole soak can be read with `summary` instead of scrolling.
|
||||
* `nic_tx` / `nic_rx` are that interface's own counter delta across the burst. If a ping passes but they stay near zero, the traffic left on the *other* NIC and the number does not belong to this one.
|
||||
* Script A runs one round as a baseline; Script B leaves it running through the soak.
|
||||
|
||||
**Fan speed is set at the start of every run**
|
||||
* `FAN_SPEED` in `config.ttl` (default 30) is applied by Script A, so a run no longer inherits whatever the previous test left the fans doing.
|
||||
* Both MAX31790 controllers are rebound first, which clears a controller left in an odd state.
|
||||
|
||||
**Stress load moved onto the platform's own job runner**
|
||||
* CPU, DDR, SSD and USB stress now go through `bgctl`, replacing the `~/hammer/tools/stress_*.py` scripts. `bgctl list` shows what is running; Script C stops everything with `bgctl stop --all`.
|
||||
* BMC DDR stress runs through `bmc-manager`, and a new BMC USB test discovers the `cdc_ncm` interface and pings across it for four hours under `systemd-run`.
|
||||
|
||||
**More of the DUT on record**
|
||||
* Script A now captures the boot image, `show version`, firmware status, system EEPROM, SSD health, TPM version and NVMe SMART data before the test starts.
|
||||
* PCIe AER now sits next to `ras-mc-ctl --summary`, and Script C closes with NVMe health so a disk that degraded during the soak is visible.
|
||||
* `dmesg` capture uses human-readable timestamps and one combined error pattern, then clears the ring buffer — so Script C's dmesg shows only what the soak produced, not everything since boot.
|
||||
* Each run opens with `hw-test-session start` and closes with `finish`; Script C copies the job logs to `/mnt/usb/jobs-<date>_<time>` so they leave the DUT with the run they belong to.
|
||||
|
||||
## 🐛 Bug fixes
|
||||
|
||||
**Script A no longer hangs waiting for ports that are already up**
|
||||
* The readiness gate required *more than* 216 ports up, but a fully cabled unit reports exactly 216 — 108 loopback pairs times two. Script A sat in the poll loop forever on the very state it was waiting for. It now proceeds at 216.
|
||||
* The comments in `wait_init.ttl` still described the old "more than" rule; they now match the code, so the off-by-one cannot be reintroduced by reading the wrong line.
|
||||
|
||||
**The macro no longer runs ahead of the DUT during the soak**
|
||||
* Script B set a 15-second wait cap for the `cdc_ncm` probe and never restored it. In Tera Term that cap is global, so it stayed in force for everything after — including the traffic setup, which walks 108 VLANs per switch unit and takes far longer. A timed-out wait returns without the prompt, leaving every later command issued a step early.
|
||||
|
||||
**Fan controller is no longer bound twice**
|
||||
* One of the two MAX31790 controllers received a second `bind` immediately after the first, which could only fail because the driver was already attached.
|
||||
|
||||
## 📦 Downloads
|
||||
|
||||
| File | Contents |
|
||||
|---|---|
|
||||
| `Script_ABC_Blanton_V1.0.7.zip` | The full Tera Term working directory, including `Blanton_Script/` to copy onto the DUT |
|
||||
|
||||
**After copying to the DUT:**
|
||||
|
||||
```bash
|
||||
chmod +x ~/Blanton_Script/*.sh # required -- see below
|
||||
grep -rlU $'\r' ~/Blanton_Script # expect no output
|
||||
```
|
||||
|
||||
The `chmod +x` is not optional. `mgmt_ping_monitor.sh` is executed rather than sourced and re-execs its own path to daemonise, and neither git (mode 100644) nor a Windows/USB copy carries the execute bit. Without it `start` fails with `Permission denied` and the later `cat` finds nothing — **the section ends up empty and nothing reports an error**.
|
||||
|
||||
## ⚠️ Before you run
|
||||
|
||||
* **Declare the switch population.** `SWB_UNIT0` / `SWB_UNIT1` in `config.ttl` say which switch units this DUT has. Traffic and the readiness gate both follow them: a single unit gets `-u 0` or `-u 1`, and with neither set the traffic stage is skipped instead of failing against hardware that is not there.
|
||||
* **Both management NICs stay up.** If they share a subnet, keep `ARP_STRICT=1` — otherwise the target's ARP can be answered by either NIC and a reply may arrive on the one that did not send.
|
||||
* **Management connectivity is exercised, not preserved.** Drive the run from the serial console.
|
||||
* **Two settings persist to `config_db.json`** and survive a reboot: LLDP is left disabled, and the 100G uplinks are left configured. Restore them before the DUT moves on.
|
||||
|
||||
## 🔗 Links
|
||||
|
||||
* [ARCHITECTURE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/ARCHITECTURE.md) — test flow, data models, constraints
|
||||
* [CLAUDE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/CLAUDE.md) — commands and the bench gotchas
|
||||
|
||||
**Full changelog:** [V1.0.5...V1.0.7](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/compare/V1.0.5...V1.0.7)
|
||||
@@ -1,7 +1,7 @@
|
||||
; =============================================================================
|
||||
; Script A for Blanton
|
||||
; Version : V1.0.6
|
||||
; Date : 2026-08-24
|
||||
; Version : V1.0.7
|
||||
; Date : 2026-08-25
|
||||
; Author : ETWen
|
||||
; =============================================================================
|
||||
; Version History:
|
||||
@@ -41,6 +41,8 @@
|
||||
; ScriptA Add Fan Ctrl (max31790 rebind + fan-speed-control.sh)
|
||||
; ScriptA Clear /host/hw-eval/current/jobs before the run
|
||||
; ScriptC Copy stress jobs log to USB, timestamped
|
||||
; utils/wait_init.ttl WT_INTERVAL 10 -> 60, fix WT_MIN comments
|
||||
; ScriptC Disable BMC USB journalctl dump
|
||||
; =============================================================================
|
||||
include "config.ttl"
|
||||
|
||||
|
||||
@@ -54,8 +54,8 @@ sendln "/usr/sbin/ras-mc-ctl --summary"
|
||||
;sendln "cat ./Blanton_Script/log/bmc_ddr.log"
|
||||
|
||||
; ========== BMC USB Test result ==========
|
||||
wait prompt_sonic_root
|
||||
sendln "journalctl -u qfx5252-bmc-usb-net-test.service --no-pager"
|
||||
;wait prompt_sonic_root
|
||||
;sendln "journalctl -u qfx5252-bmc-usb-net-test.service --no-pager"
|
||||
|
||||
; ========== 10G/1G MGMT Test result ==========
|
||||
wait prompt_sonic_root
|
||||
|
||||
@@ -4,7 +4,7 @@
|
||||
; Date : 2026-08-21
|
||||
; Author : ETWen
|
||||
; =============================================================================
|
||||
; Wait until every switch unit ENABLED below reports more than WT_MIN ports up:
|
||||
; Wait until every switch unit ENABLED below reports at least WT_MIN ports up:
|
||||
; bcmcmd -n <u> -c ps | grep -w up | wc -l
|
||||
;
|
||||
; The DUT is not always fully populated. Which units exist is declared ONCE in
|
||||
@@ -34,10 +34,15 @@
|
||||
; V3.1.0 2026-08-21 Take the population from SWB_UNIT0 / SWB_UNIT1 in
|
||||
; config.ttl instead of local copies, so this wait and the
|
||||
; traffic blocks cannot drift apart.
|
||||
; V3.1.1 2026-08-25 WT_INTERVAL 10 -> 60. Fix the WT_MIN comments: the test
|
||||
; has been `< WT_MIN` (at least) since the threshold was
|
||||
; corrected, but the text still said "more than", which is
|
||||
; the off-by-one that once hung Script A.
|
||||
; =============================================================================
|
||||
; ---- which units to wait for: SWB_UNIT0 / SWB_UNIT1, set in config.ttl ------
|
||||
WT_MIN = 216 ; an enabled unit must report MORE than this many ports up
|
||||
WT_INTERVAL = 10 ; seconds between polls
|
||||
WT_MIN = 216 ; an enabled unit must report AT LEAST this many ports up
|
||||
; (216 = 108 loopback pairs x 2, i.e. every cabled port)
|
||||
WT_INTERVAL = 60 ; seconds between polls
|
||||
; -----------------------------------------------------------------------------
|
||||
|
||||
timeout = 60 ; per-wait cap; bcmcmd ps is not instant
|
||||
|
||||