fix(scriptc): Capture the BMC USB service log to a file, not the console
journalctl now runs with -o short-iso into log/bmc_usb_net.log and is copied into the job directory with the other monitor logs. rm -f first so the file covers this run only, and the ISO timestamps line up with mgmt_ping.log and nfc_poll.log for cross-referencing. The cost, recorded rather than glossed over: it is no longer echoed to the console, so the USB copy is the only copy. That cp return value is not checked - the same shape as the nfc_polling.log filename bug, which failed silently and was only noticed back at the desk with a job archive missing a file. Folded into V1.1.6 rather than bumping: the tag has not moved on and this is the same delivery. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_014RetWKFZFG1ZHcitQAyhwM
This commit is contained in:
+6
-1
@@ -365,7 +365,7 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc
|
||||
|------|--------|------|
|
||||
| **Script A(Pre-test)** | `1_Blanton_Script_A.ttl` V1.1.6 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**(`hw-test-session finish` → `bgctl reset --yes` → `bgctl stop --all` → `bgctl list` 確認清空)→ `hw-test-session start` → **設定風扇轉速** → **等資料面就緒**(`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary` → `lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → **NFC 基線**(start → 30s → stop → report)→ 100G uplink 設定與狀態 → **一輪流量基線** → `show uptime` |
|
||||
| **Script B(Stress)** | `2_Blanton_Script_B.ttl` | `mlucas-avx2 -cpu 0:15` + `bgctl run` 的 `memtester` / SSD / USB 壓力(v1.1.5 起 SSD/USB `--runtime 86400`、BMC memtester 不帶次數 = 跑到被停) + BMC DDR(`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 4 小時 ping)→ 啟動 mgmt ping 監控 → **啟動 NFC 輪詢** → `jobs` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪 PMON + `bgctl list`/`jobs` + `pause 60`(**V1.1.4 起 margin 不在迴圈內**)|
|
||||
| **Script C(Post-test)** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + `bgctl stop --all` / `reset` + 停 BMC USB unit、mgmt ping 與 **NFC 輪詢** → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl` → `ip -s link show eth0/eth1` → `cat` mlucas log → **NFC `report`** → traffic `stop` + `report` → **BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` → **margin 掃描**(`EN_Margin`,V1.1.4 由 Script B 移來)→ `uptime` → **job log 複製到 USB(帶時戳)** → `exit` + wait『Script done』→ `hw-test-session finish` |
|
||||
| **Script C(Post-test)** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + `bgctl stop --all` / `reset` + 停 BMC USB unit、mgmt ping 與 **NFC 輪詢** → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl` **寫進 `log/bmc_usb_net.log`**(不再印在 console) → `ip -s link show eth0/eth1` → `cat` mlucas log → **NFC `report`** → traffic `stop` + `report` → **BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` → **margin 掃描**(`EN_Margin`,V1.1.4 由 Script B 移來)→ `uptime` → **job log 複製到 USB(帶時戳)** → `exit` + wait『Script done』→ `hw-test-session finish` |
|
||||
| **Script 4(Thermal / Safety)** | `4_Blanton_Script_thermal_safety.ttl` | **獨立腳本,不接 A→B→C。** Script A 式的環境建立(登入 / session / 風扇 / `wait_init` / DUT 清單 / BMC / PCIe 清除 / `pcie_bus` / PMON / dmesg)→ **滿載**(`mlucas-avx2 -cpu 0:15` 背景 + `blanton_tr518.sh start`)→ `while 1`:PMON + `TH6_SWB0/1_power_readback.sh` + `bgctl list` / `jobs`,`pause 60`。**沒有收尾段** —— 中斷後 DUT 仍在 `port cd lb=mac` / `l2 learn off` / `test mode nr=yes`,要手動 `blanton_tr518.sh stop` |
|
||||
| **SWB loopback 流量** | `blanton_traffic_linespeed <sub> [-u 0\|1\|all]` | `init`(VLAN 30..137,成對 `cdN`/`cdN+32`)→ `clear` → `start`(`tx 200 length=324 PatternRandom=yes`,v0.7.0 起)→ `stop` → `report`(per-pair TX/RX 交叉比對 PASS/FAIL);另有 `ps`(link/speed)與 `run`(一條龍)。**V0.6.0 起含 100G uplink `ce0`**(VLAN 138):它沒有 loopback 對象,靠 **ingress mirror 打回自己**維持循環,`report` 最後一列就是它,底下再接一份跨 unit summary |
|
||||
| **FPGA 暫存器存取** | `cb_fpga <fn> <addr> [data]`、`fpga_rescan` | pcimem 打 `resource0` + BAR 相對 offset,32-bit word;BDF 於 source 時自動偵測;`pmc/icb/swb0/swb1_fpga` 走 VSPI 窗口 |
|
||||
@@ -815,6 +815,11 @@ margin status、全部 VRM 軌的 Vin/Vout/Iout/Temp、CB + ICB 溫感讀值,
|
||||
- **`--runtime 86400` 是 24 小時的上限,不是「永遠」**:超過一天的 soak,SSD 與 USB 壓力會在
|
||||
第 24 小時安靜結束,剩下的時間那兩項是閒置的。Script B 每輪都印 `bgctl list`,數量變少會看得到,
|
||||
但**沒有任何東西會主動報警**。真的要跑更久,得把數字改大或加一段重啟 job 的邏輯。
|
||||
- **BMC USB 的 service log 只剩隨身碟一份**:Script C 把 `journalctl` 導進
|
||||
`log/bmc_usb_net.log` 再 `cp` 到 job 目錄,**不再印在 master console log**。
|
||||
那個 `cp` 沒有檢查回傳值(`nfc_polling.log` 檔名打錯那次就是這樣安靜失敗的),
|
||||
失敗的話這份 log 就完全消失。要嘛在 `cp` 之後補一次 `ls` 驗證,要嘛保留一份
|
||||
`cat` 到 console。
|
||||
- **`READ_VIN` / `READ_IIN` 不在 ADPM12200 手冊的 Table 3 裡**:`pwr_brick.sh` 讓它們沿用
|
||||
Voltage / Current 那兩組係數。50 V 輸入算得出來、數量級也對,但**手冊沒有明說**。要定案
|
||||
得找 ADI 確認,或找一個能獨立比對輸入電壓的量測點(`READ_VOUT` 就是靠 `show platform
|
||||
|
||||
Reference in New Issue