feat(nfc): Poll the NFC tag through the soak instead of sampling it once

nfc_polling.sh wraps blantons_nfc_validate.py in a background loop and
keeps score: start/stop/status/tail/report/clear/fg. Script A takes a
30s baseline, Script B starts the poll for the soak, Script C stops it
with the other monitors and reports.

report only reads the log, so it can be run mid-soak without disturbing
anything - and it says RUNNING so a snapshot is not read as the final
answer. Each round appends a machine-readable RESULT line, which keeps
the tally independent of the tool's wording.

ERROR is counted apart from FAIL. A round where the tool printed neither
[PASS] nor [FAIL] - crashed, missing, hung past the timeout - measured
nothing, and that is a different fault from a tag that would not read.
Rolling them together hides whichever one you are not looking for.

Two habits from earlier bugs are baked in: tail does not follow (tail -f
never returns and a macro waiting on the prompt hangs there), and the .py
is called through python3 rather than ./ (it arrives mode 100644 and a
USB copy carries no execute bit).

Also fixes Script C copying "nfc_polling.log" to the job dir when the
file is "nfc_poll.log". The cp failed, nothing checked it, and the run
finished looking fine - you would find out at the desk, with a job
archive that had no NFC log in it.

Script A -> V1.1.2.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_014RetWKFZFG1ZHcitQAyhwM
This commit is contained in:
2026-08-28 22:41:02 +08:00
co-authored by Claude Opus 5
parent c3b0d49145
commit bc2b529c3a
8 changed files with 1784 additions and 6 deletions
+6 -3
View File
@@ -188,6 +188,8 @@ Blanton_TTL_Script/
│ # eth0→TARGET_10G、eth1→TARGET_1G,兩張卡同時持續 ping
├── port_prbs_monitor.sh # 100G uplink PRBS 測試(bcmcmd phy diag
├── blanton_ber.sh # 全機 SerDes BER 掃描(phydiag prbs / prbsstat
├── nfc_polling.sh # NFC tag 背景輪詢 + PASS/FAIL 統計
├── blantons_nfc_validate.py # NFC/NCI 驗證工具(廠商提供,未修改)
├── blanton_tr518.sh # TR518 封包測試,量功耗前的負載來源
├── TH6_SWB0_power_readback.sh # SWB0 19 條軌 V×I + 總功耗
├── TH6_SWB1_power_readback.sh # SWB1 同上
@@ -342,9 +344,9 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc
| 模組 | 進入點 | 功能 |
|------|--------|------|
| **Script APre-test** | `1_Blanton_Script_A.ttl` V1.1.1 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**`hw-test-session finish``bgctl reset --yes``bgctl stop --all``bgctl list` 確認清空)→ `hw-test-session start`**設定風扇轉速****等資料面就緒**`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary``lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → 100G uplink 設定與狀態 → **一輪流量基線**`show uptime` |
| **Script BStress** | `2_Blanton_Script_B.ttl` | `mlucas-avx2 -cpu 0:15` + `bgctl run``memtester` / SSD / USB 壓力 + BMC DDR`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 4 小時 ping)→ 啟動 mgmt ping 監控 → `jobs` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪完整 PMON + margin |
| **Script CPost-test** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + `bgctl stop --all` / `reset` + 停 BMC USB unitmgmt ping → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl``ip -s link show eth0/eth1``cat` mlucas log → traffic `stop` + `report`**BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` / `uptime`**job log 複製到 USB(帶時戳)**`hw-test-session finish` |
| **Script APre-test** | `1_Blanton_Script_A.ttl` V1.1.2 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**`hw-test-session finish``bgctl reset --yes``bgctl stop --all``bgctl list` 確認清空)→ `hw-test-session start`**設定風扇轉速****等資料面就緒**`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary``lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** **NFC 基線**start → 30s → stop → report)→ 100G uplink 設定與狀態 → **一輪流量基線**`show uptime` |
| **Script BStress** | `2_Blanton_Script_B.ttl` | `mlucas-avx2 -cpu 0:15` + `bgctl run``memtester` / SSD / USB 壓力 + BMC DDR`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 4 小時 ping)→ 啟動 mgmt ping 監控 → **啟動 NFC 輪詢** `jobs` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪完整 PMON + margin |
| **Script CPost-test** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + `bgctl stop --all` / `reset` + 停 BMC USB unitmgmt ping**NFC 輪詢** → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl``ip -s link show eth0/eth1``cat` mlucas log → **NFC `report`** traffic `stop` + `report`**BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` / `uptime`**job log 複製到 USB(帶時戳)**`hw-test-session finish` |
| **SWB loopback 流量** | `blanton_traffic_linespeed <sub> [-u 0\|1\|all]` | `init`VLAN 30..137,成對 `cdN`/`cdN+32`)→ `clear``start``tx 100 length=512`)→ `stop``report`per-pair TX/RX 交叉比對 PASS/FAIL);另有 `ps`link/speed)與 `run`(一條龍)。**V0.6.0 起含 100G uplink `ce0`**VLAN 138):它沒有 loopback 對象,靠 **ingress mirror 打回自己**維持循環,`report` 最後一列就是它,底下再接一份跨 unit summary |
| **FPGA 暫存器存取** | `cb_fpga <fn> <addr> [data]``fpga_rescan` | pcimem 打 `resource0` + BAR 相對 offset32-bit wordBDF 於 source 時自動偵測;`pmc/icb/swb0/swb1_fpga` 走 VSPI 窗口 |
| **CB I2C / PMBus** | `cb_i2c_init/scan/read/write``cb_pmbus_read/write/linear16` | FPGA F3 OpenCores master**讀用 Repeated START**SMBus/PMBus 裝置必需) |
@@ -360,6 +362,7 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc
| **SerDes BER 掃描** | `blanton_ber.sh {init\|clear\|start\|stop\|report} [-u 0\|1\|all]` | 全機每個對接 port 的 PRBS BER`prbs set p=3` + `prbs get`(確認每條 lane 都鎖上)→ `prbsstat STArt Interval=30` →(等一個 interval)→ `prbsstat Ber``STOp``prbs clear``report` 一列一條 lane**BER < 1e-6 才 PASS**,最後跨 unit 的 summary 帶最差 lane。⚠️ PRBS 期間 link 顯示 DOWN、不過流量 |
| **TR518 負載** | `blanton_tr518.sh {start\|stop} [-u 0\|1\|all]` | `port cd lb=mac``l2 learn off``test mode nr=yes``tr 518 ... testphase=1`,然後 settle `TR_SETTLE_SEC`120s)再讓人量功耗。`stop` 只送 `port cd lb=none`(照 `TR518.txt`),L2 學習與 test mode **不會還原**`TR_RESTORE_*=1` 才會 |
| **SWB 軌功耗** | `TH6_SWB{0,1}_power_readback.sh` | 讀 `show platform voltage/current` **各一次**,19 條軌 V×I 與總功耗。舊版每軌各讀一次(38 次呼叫、每軌不同時刻),總和是不同瞬間的加總 |
| **NFC 讀取輪詢** | `nfc_polling.sh {start\|stop\|status\|tail\|report\|clear\|fg}` | 背景重複跑 `blantons_nfc_validate.py`,每輪追加一行機器可讀的 `RESULT=`(PASS/FAIL 取自工具自己的摘要行,兩者皆無則 **ERROR**,與 FAIL 分開計數)。`start` 會先清空 log`report` **只讀 logpolling 中隨時可跑**,並標示 `RUNNING` 免得快照被當最終結果。`tail` **不 follow** |
| **USB 目標偵測** | `usb_target.sh [-o dev\|mnt\|both\|id] [-n] [-r sec]` | 找出插入的 USB 儲存裝置,排除 `/``/host` 的底層碟(本平台可能從 USB DOM 開機),多顆時拒絕猜;掛載時會驗證真的可寫 |
| **打包交付** | `publish/publish.sh [-v Ver] [-f] [-z] [-n]` | 版號讀 Script A 檔頭,複製成 `publish/Script_ABC_Blanton_<Ver>/`,排除 `*.log`,可另出 zip |