fix(session): Clear the last run's jobs and session before starting

After a run that ended badly - Tera Term closed, DUT rebooted mid-soak,
macro stopped by hand - the stress jobs kept running and the test session
stayed open. The next run then started on a box that was already loaded.
Nothing errored; the numbers were just quietly wrong.

Script A now opens with hw-test-session finish, bgctl reset --yes,
bgctl stop --all, then bgctl list. The list is the point of the sequence:
it is the one line in the log that proves the DUT was idle at the start.

Script A -> V1.1.1.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_014RetWKFZFG1ZHcitQAyhwM
This commit is contained in:
2026-08-28 22:04:31 +08:00
co-authored by Claude Opus 5
parent 59861cf953
commit c3b0d49145
4 changed files with 65 additions and 4 deletions
+2 -1
View File
@@ -342,7 +342,7 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc
| 模組 | 進入點 | 功能 |
|------|--------|------|
| **Script APre-test** | `1_Blanton_Script_A.ttl` V1.0.7 | root 登入 → `date -s` 對時 → 清 job log → `hw-test-session start`**設定風扇轉速****等資料面就緒**`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary``lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → 100G uplink 設定與狀態 → **一輪流量基線**`show uptime` |
| **Script APre-test** | `1_Blanton_Script_A.ttl` V1.1.1 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**`hw-test-session finish``bgctl reset --yes``bgctl stop --all``bgctl list` 確認清空)→ `hw-test-session start`**設定風扇轉速****等資料面就緒**`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary``lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → 100G uplink 設定與狀態 → **一輪流量基線**`show uptime` |
| **Script BStress** | `2_Blanton_Script_B.ttl` | `mlucas-avx2 -cpu 0:15` + `bgctl run``memtester` / SSD / USB 壓力 + BMC DDR`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 4 小時 ping)→ 啟動 mgmt ping 監控 → `jobs` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪完整 PMON + margin |
| **Script CPost-test** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + `bgctl stop --all` / `reset` + 停 BMC USB unit 與 mgmt ping → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl``ip -s link show eth0/eth1``cat` mlucas log → traffic `stop` + `report`**BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` / `uptime`**job log 複製到 USB(帶時戳)**`hw-test-session finish` |
| **SWB loopback 流量** | `blanton_traffic_linespeed <sub> [-u 0\|1\|all]` | `init`VLAN 30..137,成對 `cdN`/`cdN+32`)→ `clear``start``tx 100 length=512`)→ `stop``report`per-pair TX/RX 交叉比對 PASS/FAIL);另有 `ps`link/speed)與 `run`(一條龍)。**V0.6.0 起含 100G uplink `ce0`**VLAN 138):它沒有 loopback 對象,靠 **ingress mirror 打回自己**維持循環,`report` 最後一列就是它,底下再接一份跨 unit summary |
@@ -378,6 +378,7 @@ Script A ── logopen Logs/Blanton_Margin_<ts>.log ──┐ (之後所有畫
├─ 登入 admin → sudo -i → root@sonic:~# │
├─ date -s "<host 時間>" ← 讓 DUT 時戳可對照
├─ rm /host/hw-eval/jobs/* ← 清掉上一輪的 job log
├─ hw-test-session finish / bgctl reset / stop --all / list (收前一輪)
├─ hw-test-session start / log / status
├─ 風扇:max31790 unbind→sleep→bind18-0020 與 25-0020 各一次)
│ → fan-speed-control.sh <FAN_SPEED> → 回答 y 確認 │