@@ -215,7 +215,7 @@ Blanton_TTL_Script/
|
||||
├── blanton_multiphase_margin.sh # 多相 VRM margin(原生 i2c,38 條軌)
|
||||
├── pwr_brick.sh # PDB / CPB power brick 讀值(VI2C ch4)
|
||||
├── nfc_polling.sh # NFC tag 背景輪詢 + PASS/FAIL 統計
|
||||
├── blantons_nfc_validate.py # NFC/NCI 驗證工具(廠商提供,未修改)
|
||||
├── blantons_nfc_validate.py # NFC/NCI 驗證工具(廠商提供,未修改;V1.2.7 起為 v2.5)
|
||||
├── blanton_tr518.sh # TR518 封包測試,量功耗前的負載來源
|
||||
├── TH6_SWB0_power_readback.sh # SWB0 19 條軌 V×I + 總功耗
|
||||
├── TH6_SWB1_power_readback.sh # SWB1 同上
|
||||
@@ -388,7 +388,7 @@ PROFILE_CHANNELS=( "0:high:8" "1:low:8" ... ) # "channel:operation:change_perc
|
||||
|
||||
| 模組 | 進入點 | 功能 |
|
||||
|------|--------|------|
|
||||
| **Script A(Pre-test)** | `1_Blanton_Script_A.ttl` V1.2.6 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**(`hw-test-session finish` → `bgctl reset --yes` → `bgctl stop --all` → `bgctl list` 確認清空)→ `hw-test-session start` → **設定風扇轉速** → **等資料面就緒**(`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary` → `lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → **NFC 基線**(start → 30s → stop → report)→ 100G uplink 設定與狀態 → **`unused_lanes.sh off`**(V1.2.6)→ **BER 基線掃描**(依 `SWB_UNIT`,V1.2.1 新增)→ **一輪流量基線**(V1.2.6 起兩 unit 時夾 FDR,sleep 40) → **SerDes DSC 基線**(`EN_TX_FIR`)→ `show uptime` |
|
||||
| **Script A(Pre-test)** | `1_Blanton_Script_A.ttl` V1.2.7 | root 登入 → `date -s` 對時 → 清 job log → **收掉前一輪殘留**(`hw-test-session finish` → `bgctl reset --yes` → `bgctl stop --all` → `bgctl list` 確認清空)→ `hw-test-session start` → **設定風扇轉速** → **等資料面就緒**(`wait_init.ttl`)→ DUT 清單(boot/version/fwutil/syseeprom/ssdhealth/TPM/NVMe)→ BMC enroll + version/status → source bash 工具 → 清/讀 7 組 PCIe AER + `ras-mc-ctl --summary` → `lspci` → margin → PMON → dmesg → **10G/1G 管理網路 ping** → **NFC 基線**(start → 30s → stop → report)→ 100G uplink 設定與狀態 → **`unused_lanes.sh off`**(V1.2.6)→ **BER 基線掃描**(依 `SWB_UNIT`,V1.2.1 新增)→ **一輪流量基線**(V1.2.6 起兩 unit 時夾 FDR,sleep 40) → **SerDes DSC 基線**(`EN_TX_FIR`)→ `show uptime` |
|
||||
| **Script B(Stress)** | `2_Blanton_Script_B.ttl` | **V1.1.8 起 `mlucas-avx2 -cpu 0:15` 由 `systemd-run --unit=mlucas-amm`(`Type=exec`、`Restart=always`)啟動,不再是 shell 的 `&` 背景 job** + `bgctl run` 的 `memtester` / SSD / USB 壓力(v1.1.7 起 SSD/USB 的 `--runtime`/`--passes` 讀 `config.ttl` 的 `SSD_RUNTIME`/`SSD_COUNT`、`USB_RUNTIME`/`USB_COUNT`;BMC memtester 不帶次數 = 跑到被停) + BMC DDR(`bmc-manager run memtester`)→ BMC USB net test(探測 cdc_ncm 介面,`systemd-run` 掛 `BMC_USB_RUNTIME` 秒的 ping,V1.1.8 前寫死 4 小時)→ 啟動 mgmt ping 監控 → **啟動 NFC 輪詢** → `jobs` / `systemctl is-active mlucas-amm` / `bgctl list` → traffic(依 `SWB_UNIT`)→ `while 1` 每輪 PMON + `bgctl list`/`jobs`/`systemctl is-active mlucas-amm` + `sleep 60`(**V1.1.4 起 margin 不在迴圈內**;V1.2.0 起等待走 DUT 端 `sleep` 而非 macro 端 `pause`)|
|
||||
| **Script C(Post-test)** | `3_Blanton_Script_C.ttl` | `kill $(jobs -p)` + **`systemctl stop mlucas-amm`**(systemd unit 不是 shell job,`jobs -p` 抓不到)+ `bgctl stop --all` / `reset` + 停 BMC USB unit、mgmt ping 與 **NFC 輪詢** → PMON + dmesg → 7 組 AER + `ras-mc-ctl` → BMC USB `journalctl` **寫進 `log/bmc_usb_net.log`**(不再印在 console) → `ip -s link show eth0/eth1` → `cat` mlucas log(並 `cp` 進 job 目錄一起帶走)→ **NFC `report`** → traffic `stop` + `report` → **SerDes DSC 收尾**(`EN_TX_FIR`)→ **BER 掃描**(依 `SWB_UNIT`)→ NVMe 健康 → `show reboot-cause` → **margin 掃描**(`EN_Margin`,V1.1.4 由 Script B 移來)→ `uptime` → **job log 複製到 USB(帶時戳)** → `exit` + wait『Script done』→ `hw-test-session finish` |
|
||||
| **Script 4(Thermal / Safety)** | `4_Blanton_Script_thermal_safety.ttl` | **獨立腳本,不接 A→B→C。** Script A 式的環境建立(登入 / session / 風扇 / `wait_init` / DUT 清單 / BMC / PCIe 清除 / `pcie_bus` / PMON / dmesg)→ **滿載**(`mlucas-avx2 -cpu 0:15`,V1.1.8 起與 Script B 同樣掛成 `mlucas-amm` systemd unit + `blanton_tr518.sh start`)→ `while 1`:PMON + `TH6_SWB0/1_power_readback.sh` + `avt_pmpower.sh`(CPU 封裝功耗,V1.2.3)+ `bgctl list` / `jobs` / `systemctl is-active mlucas-amm`,`pause 60`。**沒有收尾段** —— 中斷後 DUT 仍在 `port cd lb=mac` / `l2 learn off` / `test mode nr=yes`,且 CPU 仍滿載,要手動 `blanton_tr518.sh stop` + `systemctl stop mlucas-amm` |
|
||||
@@ -819,7 +819,7 @@ margin status、全部 VRM 軌的 Vin/Vout/Iout/Temp、CB + ICB 溫感讀值,
|
||||
- [ ] `CHANGELOG.md`:延續三支腳本頂端的 Version History,集中成一份
|
||||
- [ ] 三支腳本的 header 版號與 `CHANGELOG.md` 對齊,`config.ttl` 加 `script_version` 並寫進 log 開頭
|
||||
- [ ] `docs/TTL_Script_Blanton_Status_*.xlsx` 更新為全 OK,或把剩餘項目移進 Future Extensions
|
||||
- [x] 打 git tag,push `nas` + `gitea`(已至 `V1.2.6`;`publish/` 依 Script A 檔頭版號打包)
|
||||
- [x] 打 git tag,push `nas` + `gitea`(已至 `V1.2.7`;`publish/` 依 Script A 檔頭版號打包)
|
||||
|
||||
**驗收條件:** 從 zip 解壓到一台乾淨的測試 NB,照 README 操作,不看原始碼就能完成一輪 A→B→C
|
||||
並產出 summary;`publish/` 內容與 git tag 一致。
|
||||
|
||||
@@ -9,7 +9,7 @@ DUT 端的取數能力由一組 **bash 工具庫** 提供(CB FPGA `pcimem` →
|
||||
|
||||
完整架構見 [ARCHITECTURE.md](ARCHITECTURE.md)。
|
||||
|
||||
**目前狀態(2026-10-21)**:Script A 為 **V1.2.6**(A 集中記錄所有 TTL 的變更)。涵蓋
|
||||
**目前狀態(2026-10-22)**:Script A 為 **V1.2.7**(A 集中記錄所有 TTL 的變更)。涵蓋
|
||||
PCIe AER / DDR EDAC / PMON+TPM / 電壓 margin(9 顆 LTC2980)/ SWB loopback 線速流量 /
|
||||
10G+1G 管理網路 ping / BMC DDR 與 USB / NVMe 健康,壓力層走平台的 `bgctl`。
|
||||
switch unit 數量由 `config.ttl` 的 `SWB_UNIT0` / `SWB_UNIT1` 宣告,風扇轉速由 `FAN_SPEED` 指定
|
||||
@@ -44,13 +44,14 @@ NFC tag 讀取由 `nfc_polling.sh` 背景輪詢(A 做基線、B 起、C 停並
|
||||
`retimer_lanes.sh` / `unused_lanes.sh`(把沒接線的 retimer lane / TH6 port 關 TX),以及
|
||||
`5_1_Blanton_Script_Boot_Cycle_Fast.ttl`(Script 5 拿掉流量那段,只留 `ps`)。
|
||||
**V1.2.6 起 FDR 統計(`blanton_fdr.sh`,`phydiag fdrstat`)接進流量**:A 包住流量基線(sleep 15→40)、
|
||||
B 在 soak 前 start、C 收尾 rdcnt + stop,**只在兩個 unit 都開時才跑**。Script A 另在 BER 前先 `unused_lanes.sh off`,
|
||||
B 在 soak 前 start、每輪 rdcnt、C 收尾 rdcnt + stop,**只在兩個 unit 都開時才跑**。Script A 另在 BER 前先 `unused_lanes.sh off`,
|
||||
⚠️ **沒有任何地方再 `on` 回來**。
|
||||
**V1.2.7**:`blanton_fdr.sh` 預設 port 改成只含有接線的 port(同 traffic 的 `TL_PS_PORTS`,不含 268);`blantons_nfc_validate.py` 換成客戶 v2.5(`qfx5252-nfc-validate` 改名,`nfc_polling.sh` 不用改)。
|
||||
以及 **`5_Blanton_Script_Boot_Cycle.ttl`**(重開機循環,**獨立跑不接 A→B→C**:登入 → 風扇 →
|
||||
Check Pt1~Pt13 → `reboot` → `wait "Booting in blind mode"`,`cnt_cycle` 每輪遞增,`while 1` 無止境,
|
||||
要停就關 Tera Term 的 macro)。**尚未上機驗證**。
|
||||
流程圖:`docs/Blanton_Test_Flow.drawio`。
|
||||
最後一次發布是 **V1.2.6**;SWB 的 I2C 通道與位址已於 2026-08-19 上機驗證。
|
||||
最後一次發布是 **V1.2.7**;SWB 的 I2C 通道與位址已於 2026-08-19 上機驗證。
|
||||
margin 的 `VNOM` 已於 2026-08-30 改為 Blanton 實測中位數(144 條軌中 86 條上調 0.8~2.5%)。
|
||||
交付用 `./publish/publish.sh` 打包。
|
||||
|
||||
@@ -196,7 +197,7 @@ sleep 30 # 至少等一個 interval 再 rep
|
||||
~/Blanton_Script/blanton_fdr.sh clear # fdrstat clear
|
||||
~/Blanton_Script/blanton_fdr.sh rdcnt # fdrstat Counters(Interval 結算後才讀,A 用 sleep 40)
|
||||
~/Blanton_Script/blanton_fdr.sh stop # fdrstat STOp ⚠️ 關鍵字是類推的,未上機驗證
|
||||
# -u 0|1 單邊;-i <sec> 改 Interval;-n dry-run。ports 預設 '1-259,270-565'(FDR_PORTS 可改)
|
||||
# -u 0|1 單邊;-i <sec> 改 Interval;-n dry-run。ports 預設同 traffic 的 TL_PS_PORTS(只含有接線的 port,不含 268;FDR_PORTS 可改)
|
||||
|
||||
# ── 沒接線的 retimer lane / TH6 port 關 TX(V1.2.5;V1.2.6 起 Script A 會 off,沒人 on 回來)──
|
||||
./Blanton_Script/unused_lanes.sh status # 兩 unit 全部列出 rx_lock / tx_off
|
||||
|
||||
@@ -10,7 +10,7 @@
|
||||
|
||||
**FDR runs alongside the traffic test in Script A, B and C**
|
||||
* **Script A** wraps its traffic baseline: `fdr start` after `init`, `fdr clear` after `clear`, `fdr rdcnt` after the run, `fdr stop` after the traffic stop. The traffic run is now **40 s instead of 15 s**, so the counters are read after the first 30 s interval has been published — the same rule as `prbsstat Ber`.
|
||||
* **Script B** starts and clears FDR with the traffic setup, before the soak loop — the counters run for the whole soak.
|
||||
* **Script B** starts and clears FDR with the traffic setup, before the soak loop — the counters run for the whole soak — and reads them (`rdcnt`) in every soak round, after the Tray ID stress.
|
||||
* **Script C** reads them (`rdcnt`) before stopping the traffic and stops FDR after it — the closing read of the counters Script B started.
|
||||
|
||||
**Script A turns off the unused lanes before the BER baseline**
|
||||
@@ -32,6 +32,7 @@ grep -rlU $'\r' ~/Blanton_Script # expect no output
|
||||
* **`chmod +x` after deploying.** `blanton_fdr.sh`, `unused_lanes.sh` and `retimer_lanes.sh` are all called by path; `unused_lanes.sh` also refuses to start if `retimer_lanes.sh` is not executable.
|
||||
* **`blanton_fdr.sh stop` sends `fdrstat STOp` — that keyword is inferred from `prbsstat STOp` and has not been checked on the bench.** `bcmcmd` exits 0 even when the BCM shell rejects a command, so if it is wrong, FDR keeps running and only the log shows it. Check the first run.
|
||||
* **FDR only runs when both switch units are enabled** (`SWB_UNIT0 = SWB_UNIT1 = 1`). The single-unit branches have no FDR, and Script A's single-unit traffic run is still 15 s.
|
||||
* **Script B's per-round `fdr rdcnt` is not gated by the unit settings** — with one unit enabled, FDR was never started and each round just logs whatever `fdrstat Counters` returns.
|
||||
* **Nothing turns the unused lanes back on.** Script C has no `unused_lanes.sh on`; run it by hand when the DUT is needed in its normal state. Whether a reboot clears it has not been checked.
|
||||
* **`unused_lanes.sh off` is not gated by `SWB_UNIT0` / `SWB_UNIT1`** — it always acts on both boards.
|
||||
* **`blanton_ber.sh` (Script A / C) still uses `p=3` and `sleep 30`**; see v1.2.5.
|
||||
|
||||
@@ -0,0 +1,47 @@
|
||||
# v1.2.7 — FDR on the cabled ports only, and the vendor NFC tool updated to v2.5
|
||||
|
||||
## 🐛 Bug fixes
|
||||
|
||||
**`blanton_fdr.sh` no longer prints the uncabled ports** (v1.0.1)
|
||||
* The default port list was `'1-259,270-565'`, which also covered ports nothing is cabled to (cd15..19, cd47..51, cd111..115, ...).
|
||||
* It is now the cabled-port list from `blanton_traffic_linespeed.sh` (`TL_PS_PORTS`), the same one `blanton_ber_debug.sh` uses:
|
||||
`1-24,40-96,112-168,184-240,256-259,270-308,310-327,342-380,382-399,414-452,454-471,486-524,526-543,558-565`.
|
||||
* Script A, B and C pick this up with no change to the TTLs.
|
||||
|
||||
## 📦 Vendor tool update
|
||||
|
||||
**`blantons_nfc_validate.py` v2.3 → v2.5** — the customer's `qfx5252-nfc-validate`, renamed to keep the name `nfc_polling.sh` calls.
|
||||
* New: `--read-ndef` (Type 2 / Type 4 NDEF, Text and AMD FRU records), `--write-ndef` / `--set-location`, `--max-ndef-bytes`; NCI data packets with credit flow control.
|
||||
* Fixed: a `FileNotFoundError` crash while listing the processes that hold the NFC device open.
|
||||
* Bad arguments now print `[FAIL]` and exit 1 — `nfc_polling.sh` counts that as **FAIL**, not ERROR.
|
||||
* The default `test --debug` output (`[PASS]` / `[FAIL]` lines, `NFCID1=`) is unchanged, so `nfc_polling.sh` is not modified.
|
||||
|
||||
## 📦 Downloads
|
||||
|
||||
| File | Contents |
|
||||
|---|---|
|
||||
| `Script_ABC_Blanton_V1.2.7.zip` | The full Tera Term working directory, including `Blanton_Script/` to copy onto the DUT |
|
||||
|
||||
```bash
|
||||
chmod +x ~/Blanton_Script/*.sh
|
||||
grep -rlU $'\r' ~/Blanton_Script # expect no output
|
||||
python3 ~/Blanton_Script/blantons_nfc_validate.py --version # expect 2.5
|
||||
```
|
||||
|
||||
## ⚠️ Before you run
|
||||
|
||||
* **Port 268 (ce0, 100G uplink) is not in the FDR list** — as before. Add it with `FDR_PORTS="...,268"` if FDR is wanted there.
|
||||
* **The cabled-port list now lives in three scripts** — `blanton_traffic_linespeed.sh`, `blanton_ber_debug.sh`, `blanton_fdr.sh`. Change all three when the cabling changes.
|
||||
* **Never put the NFC write flags (`--write-ndef`, `--set-location`, `--confirm-write`) in `NFC_ARGS`** — polling would rewrite the tag every round.
|
||||
* **`blanton_fdr.sh stop` (`fdrstat STOp`) is still unverified on the bench**; see v1.2.6.
|
||||
* **Nothing turns the unused lanes back on**; run `unused_lanes.sh on` by hand. See v1.2.6.
|
||||
* **`blanton_ber.sh` (Script A / C) still uses `p=3` and `sleep 30`**; see v1.2.5.
|
||||
* **Script 4 has no teardown**: finish it with `blanton_tr518.sh stop` **and** `systemctl stop mlucas-amm`.
|
||||
* **`FAN_SPEED` is 100.**
|
||||
|
||||
## 🔗 Links
|
||||
|
||||
* [ARCHITECTURE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/ARCHITECTURE.md) — test flow, data models, constraints
|
||||
* [CLAUDE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/CLAUDE.md) — commands and the bench gotchas
|
||||
|
||||
**Full changelog:** [V1.2.6...V1.2.7](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/compare/V1.2.6...V1.2.7)
|
||||
@@ -1,7 +1,7 @@
|
||||
; =============================================================================
|
||||
; Script A for Blanton
|
||||
; Version : V1.2.6
|
||||
; Date : 2026-10-21
|
||||
; Version : V1.2.7
|
||||
; Date : 2026-10-22
|
||||
; Author : ETWen
|
||||
; =============================================================================
|
||||
; Version History:
|
||||
@@ -874,9 +874,31 @@
|
||||
; ScriptB fdr start + fdr clear with the traffic setup, before the loop
|
||||
; (SWB_UNIT0 = SWB_UNIT1 = 1 only) - the counters run for the
|
||||
; whole soak
|
||||
; fdr rdcnt in every soak round, after the Tray ID stress
|
||||
; !! not gated by SWB_UNIT0 / SWB_UNIT1, unlike the start -
|
||||
; with one unit enabled FDR was never started, and the
|
||||
; round just logs whatever fdrstat Counters returns
|
||||
; ScriptC fdr rdcnt before traffic stop, fdr stop after it
|
||||
; (SWB_UNIT0 = SWB_UNIT1 = 1 only) - the closing read of the
|
||||
; counters Script B started, bracketing the soak
|
||||
; V1.2.7 2026-10-22 Blanton_Script/blanton_fdr.sh v1.0.1 - default ports are the cabled ports only
|
||||
; '1-259,270-565' -> the TL_PS_PORTS list of
|
||||
; blanton_traffic_linespeed.sh (same as blanton_ber_debug.sh)
|
||||
; The old range also printed the uncabled ports (cd15..19,
|
||||
; cd47..51, cd111..115, ...)
|
||||
; !! port 268 (ce0) is still left out - add ',268' through
|
||||
; FDR_PORTS if FDR is wanted on the 100G uplink
|
||||
; !! the port list now lives in three scripts (traffic,
|
||||
; BER debug, FDR) - change all three when the cabling changes
|
||||
; Blanton_Script/blantons_nfc_validate.py Vendor tool v2.3 -> v2.5 (qfx5252-nfc-validate, renamed)
|
||||
; Adds --read-ndef / --write-ndef / --set-location, NCI data
|
||||
; packets with credit flow control; fixes a FileNotFoundError
|
||||
; crash while listing the processes holding the NFC device
|
||||
; Bad arguments now print [FAIL] and exit 1, so nfc_polling
|
||||
; counts them as FAIL instead of ERROR
|
||||
; The default "test --debug" output ([PASS]/[FAIL], NFCID1=)
|
||||
; is unchanged - nfc_polling.sh is not modified
|
||||
; !! never put the write flags in NFC_ARGS
|
||||
; =============================================================================
|
||||
include "config.ttl"
|
||||
|
||||
|
||||
@@ -194,6 +194,10 @@ while 1
|
||||
; ========== Tray ID Stress Test ==========
|
||||
wait prompt_sonic_root
|
||||
sendln "~/Blanton_Script/tray_id_stress.sh"
|
||||
|
||||
; ========== FDR Counter Read ==========
|
||||
wait prompt_sonic_root
|
||||
sendln "~/Blanton_Script/blanton_fdr.sh rdcnt"
|
||||
|
||||
wait prompt_sonic_root
|
||||
sendln "sleep 60"
|
||||
|
||||
@@ -7,6 +7,11 @@
|
||||
# 'phydiag <ports> fdrstat ...' through bcmcmd, the same
|
||||
# way blanton_ber_debug.sh drives prbsstat. Every bcmcmd
|
||||
# output is printed as is -- no parsing, no PASS/FAIL.
|
||||
# V1.0.1 2026-10-22 Change: default FDR_PORTS is now the cabled-port list of
|
||||
# blanton_traffic_linespeed.sh (TL_PS_PORTS), not
|
||||
# '1-259,270-565' -- the old range also printed the
|
||||
# uncabled ports (cd15..19, cd47..51, ...). Port 268 (ce0)
|
||||
# is still left out; add ',268' through FDR_PORTS.
|
||||
#
|
||||
# Sub-commands (each one runs on unit 0, then unit 1):
|
||||
# start phydiag '<ports>' fdrstat STArt bin_group=both Interval=30
|
||||
@@ -27,13 +32,16 @@
|
||||
# -n dry run: print the bcmcmd lines, do not run them
|
||||
#
|
||||
# Env overrides:
|
||||
# BCMCMD_CMD=bcmcmd FDR_PORTS=1-259,270-565 FDR_INTERVAL=30
|
||||
# FDR_BIN_GROUP=both
|
||||
# BCMCMD_CMD=bcmcmd FDR_INTERVAL=30 FDR_BIN_GROUP=both
|
||||
# FDR_PORTS="1-24,40-96,..." (default: the cabled ports, same list as
|
||||
# TL_PS_PORTS in blanton_traffic_linespeed.sh
|
||||
# and BER_PORTS in blanton_ber_debug.sh; no 268)
|
||||
# =============================================================================
|
||||
|
||||
BCMCMD_CMD="${BCMCMD_CMD:-bcmcmd}"
|
||||
FDR_UNITS="0 1"
|
||||
FDR_PORTS="${FDR_PORTS:-1-259,270-565}"
|
||||
# Cabled ports only -- keep in sync with TL_PS_PORTS in blanton_traffic_linespeed.sh
|
||||
FDR_PORTS="${FDR_PORTS:-1-24,40-96,112-168,184-240,256-259,270-308,310-327,342-380,382-399,414-452,454-471,486-524,526-543,558-565}"
|
||||
FDR_INTERVAL="${FDR_INTERVAL:-30}"
|
||||
FDR_BIN_GROUP="${FDR_BIN_GROUP:-both}"
|
||||
FDR_DRY_RUN=0
|
||||
|
||||
File diff suppressed because it is too large
Load Diff
Reference in New Issue
Block a user