Files
etwenandClaude Opus 5.5 4db9b45ce7 docs: Record V1.2.4 in Script A's history and add the release note
Script A: header to V1.2.4 / 2026-10-01; entries for tray_id_stress.sh,
the Script A and Script B hooks, and 6_Blanton_Script_BER_Cycle.ttl,
with notes on the exec bit, the sleep-vs-Interval rule, the hard-coded
BDF, the hostname, the SONiC-only fan setting and the placeholder
password.

CLAUDE.md: status and last release to V1.2.4; the Tray ID stress and the
BER cycle in the overview; a commands block for tray_id_stress.sh; a
gotcha that prbsstat Ber must be read after the first interval is
published, and that Script A / C's own BER (Interval=30, sleep 30) sits
on that edge and has not been verified.

ARCHITECTURE.md: Script A ref and the tag checkbox to V1.2.4; Script 5's
current file name and the new macro 6 in the tree; tray_id_stress.sh in
the tree.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UniUXkxgCG2Ty74advL8Pd
2026-10-01 13:32:14 +08:00

55 lines
4.3 KiB
Markdown
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# v1.2.4 — Tray ID I2C stress in Script A and B, and a Diag / SONiC BER cycle that reads the BER correctly
## ✨ New features
**`tray_id_stress.sh` — Tray ID I2C write / read-back stress**
* Buses `34` / `35` / `38` / `39`, device `0x70`, register `0x02`. Each bus gets `0xA5` written and read back, then `0x5A` written and read back — the two patterns put every bit in both states.
* One line per step (`PASS` / `FAIL` / `ERROR`), then a per-bus **Summary** table and a single `Tray ID stress RESULT: PASS|FAIL` line. Exit `0` = all PASS, `1` = any FAIL or I2C error, `2` = bad arguments.
* `FAIL` (the read worked but returned the wrong value) and `ERROR` (`i2cset` / `i2cget` itself failed) are counted separately, because they point at different faults.
* The original register value is read first and **written back at the end**, verified by a read. `-R` skips that; `-n N` repeats the whole sequence N times. Buses, address, register and patterns are editable at the top of the file.
**Script A and Script B run it**
* **Script A** runs one pass after `show_dmesg` as the baseline.
* **Script B** runs one pass in every soak round, before `sleep 60` — 12 writes per round, registers restored each time.
**`6_Blanton_Script_BER_Cycle.ttl` — Diag ↔ SONiC BER cycle (standalone)**
* Each cycle measures PRBS BER on unit 0 in the Diag OS, cold-boots into SONiC, measures again, and cold-boots back to Diag. `while 1`, no end. The boot target is picked in the BIOS Boot Manager (`USB Device` = Diag, `Hard Drive` = SONiC).
* Log: `Logs\Blanton_BER_Cycle_<ts>.log`, timestamps always on.
## 🐛 Bug fixes
**`prbsstat Ber` was read before the first interval had been published — BER read 40–60× low**
* The BER cycle originally read `prbsstat Ber` 10 s after `prbsstat STArt Interval=30`. Checked against the error counts that `prbs get` reports in the same cycle, that read **Diag ~60× low and SONiC ~40× low**.
* Moving to `sleep 30` (equal to the interval) fixed SONiC but **not Diag**: its `Ber` goes out 30.15 s after `STArt`, just before the first interval is published. SONiC's `bcmcmd` adds ~0.3 s and just makes it.
* The macro now uses **`Interval=30` + `sleep 40`**. Over 73 cycles both sides agree with the `prbs get` estimate to within 0.1 decade. The rule: **the sleep must be longer than the interval.**
## 📦 Downloads
| File | Contents |
|---|---|
| `Script_ABC_Blanton_V1.2.4.zip` | The full Tera Term working directory, including `Blanton_Script/` to copy onto the DUT |
```bash
chmod +x ~/Blanton_Script/*.sh
grep -rlU $'\r' ~/Blanton_Script # expect no output
```
## ⚠️ Before you run
* **`chmod +x` after deploying.** Script A and B call `tray_id_stress.sh` by path; without the exec bit every call is `Permission denied` and the round carries on without the check.
* **Any BER log taken before 2026-09-30 14:13 reads 40–60× low** (BER cycle with `sleep ≤ Interval`). Relative Diag-vs-SONiC trends are usable; absolute values are not.
* **Script A / C's BER is the same edge case**: `blanton_ber.sh start` (Interval=30) → `sleep 30` → `report`, on SONiC. Whether it catches the first interval has **not been verified**. Lengthening that sleep to 40 is the safe change.
* **The BER cycle's SONiC → Diag boot writes a hard-coded BDF** (`pcimem /sys/bus/pci/devices/0000:05:00.0/resource0 0x480`). Check the CB FPGA BDF on every unit before running it.
* **The BER cycle expects the hostname `sonic`.** A unit with another hostname (e.g. `Margin02`) needs `prompt_sonic` / `prompt_sonic_root` edited, or the macro waits forever.
* **The BER cycle sets the fan to 30 % on the SONiC side only** — SONiC runs ~11 °C hotter than Diag, a variable in any Diag-vs-SONiC comparison.
* **Its SONiC password is the `YourPaSsWoRd` placeholder**, and it does not read `config.ttl` or `secret/`.
* **Script 4 has no teardown**: finish it with `blanton_tr518.sh stop` **and** `systemctl stop mlucas-amm`.
* **`FAN_SPEED` is 100.**