etwenandClaude Opus 5 78a8f641c9 fix(scriptc): Capture the BMC USB service log to a file, not the console
journalctl now runs with -o short-iso into log/bmc_usb_net.log and is
copied into the job directory with the other monitor logs. rm -f first so
the file covers this run only, and the ISO timestamps line up with
mgmt_ping.log and nfc_poll.log for cross-referencing.

The cost, recorded rather than glossed over: it is no longer echoed to
the console, so the USB copy is the only copy. That cp return value is
not checked - the same shape as the nfc_polling.log filename bug, which
failed silently and was only noticed back at the desk with a job archive
missing a file.

Folded into V1.1.6 rather than bumping: the tag has not moved on and this
is the same delivery.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_014RetWKFZFG1ZHcitQAyhwM
2026-09-02 21:44:06 +08:00

75 lines
5.9 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# v1.1.6 — The PDB bricks were never being asked the right question
## 🐛 Bug fixes
**Every PDB reading was `NA`, and the cause was a page number written in the wrong base**
* The four ADPM12200 bricks put each measurement on its own PMBus PAGE, and the page has to be written before every read. The bring-up spreadsheet listed those page numbers in decimal but with an `0x` prefix, so four of the five selected the wrong page:
| Reading | Datasheet PAGE | Should send | Spreadsheet said |
|---|---|---|---|
| Vin | 9 | `0x09` | `0x00` |
| Iin | 10 | `0x0A` | `0x10` |
| Vout | 2 | `0x02` | `0x02` ✅ |
| Iout | 14 | `0x0E` | `0x14` |
| Temp | 18 | `0x12` | `0x18` |
* Only Vout worked — because 2 reads the same in either base. That is why Iin and Iout answered `0xFFFF` and the temperature answered `0x0000`, and why a Vin scaling had to be invented to make 50 V appear.
* `blanton_pwr_data.sh` sends no page at all (its PDB table has `page "-"`), which is the reason it reports the whole PDB section as `NA`.
## ✨ New features
**`pwr_brick.sh` — the five power bricks, read properly**
* `show` prints Vin / Iin / Vout / Iout / Temp for all five: `SWB0.PU207` (0x62), `SWB0.PU13` (0x63), `SWB1.PU332` (0x60), `SWB1.PU85` (0x61) and `CPB.PU37` (0x26). `-r` adds the raw words.
* Conversions come from the datasheet's DIRECT equation, `X = (1/m)(Y × 10⁻ᴿ b)`, with Table 3's coefficients: voltage `Y × 8 mV`, current `Y × 0.04 A`, temperature `Y × 0.01 °C`.
* **Cross-checked, not assumed**: `READ_VOUT` returns `0x05D4` → 1492 × 8 = 11936 mV, which is exactly the figure `show platform voltage` reports for that rail from a completely separate sensor path.
* `CPB.PU37` is a different part — no page writes and its own scaling — and is handled separately.
* The datasheet is now in the repo (`docs/ADPM12200CMLZxx_DS_*.pdf`) so the pages and coefficients can be checked without hunting for it.
**Every value is validated before it is printed**
* This bus corrupts the **high byte only**. That turns `11.98 V` into `32.00 V` — positive, plausible in magnitude, and invisible to any "reject 0xFFFF" filter. Each value is re-read (up to `PB_TRIES`, default 8) until it is not `0xFFFF`, not `0x0000`, and lands inside a plausibility window.
* `0x0000` is rejected as a raw word for the same reason: on the temperature register it decodes to a perfectly believable 0 °C.
**Complementary margin profiles per board**
* `comboA` / `comboB` for CB and each SWB CONN. `comboB` is `comboA` with every direction flipped, so running both covers each rail high and low while its neighbours sit the other way.
* NC channels stay at `nominal` in both — there is nothing to margin on an unused rail (CONN14 CH10/11/13, CONN15 CH10).
**The BMC USB service log is captured again — to a file**
* Script C's `journalctl` dump had been commented out, so that service log reached nothing at all. It now runs with `-o short-iso` into `log/bmc_usb_net.log` and is copied into the job directory for the USB archive. The ISO timestamps line up with the other monitor logs, and `rm -f` first keeps the file to one run.
* **It is no longer printed to the console**, so the USB copy is the only copy. If that `cp` fails — and nothing checks it — the service log is gone. Check the job directory before packing up.
## 📦 Downloads
| File | Contents |
|---|---|
| `Script_ABC_Blanton_V1.1.6.zip` | The full Tera Term working directory, including `Blanton_Script/` to copy onto the DUT |
**After copying to the DUT:**
```bash
chmod +x ~/Blanton_Script/*.sh # see below
grep -rlU $'\r' ~/Blanton_Script # expect no output
```
`blanton_ber.sh`, `nfc_polling.sh`, `blanton_tr518.sh`, `blanton_multiphase_margin.sh`, `pwr_brick.sh` and the two `TH6_SWB*_power_readback.sh` are invoked through `./` or `~/`, so they need the execute bit along with `bmc_monitor.sh` and `usb_target.sh` — neither git nor a Windows/USB copy carries it reliably.
## ⚠️ Before you run
* **`READ_VIN` and `READ_IIN` are not in the datasheet's coefficient table.** They are decoded here with the voltage and current coefficients — consistent with a ~50 V input, but not stated by the datasheet. Anything quoting brick Vin should have that confirmed first. `PB_VIN_M` / `PB_IIN_M` are where to change it.
* **The BMC USB service log only exists on the USB stick.** It is not in the master console log any more.
* **`NA` has two meanings**: nothing readable, or read but outside its plausibility window. Use `PB_TRIES=1 ./Blanton_Script/pwr_brick.sh show -r` to see the unretried raw words and tell them apart.
* **Margin profiles are positional.** `comboA_SWB_CONN13` applied to a CONN16 board margins the wrong rails and nothing detects it.
* **`blanton_multiphase_margin.sh save` is permanent**, and it must not be mixed with `margin.sh` — same rails, two access paths, no interlock.
* **A soak longer than 24 hours needs the stress runtimes raised** — `--runtime 86400` is a ceiling.
* **Script 4 (thermal/safety) has no teardown** — finish with `blanton_tr518.sh stop` and `kill $(jobs -p)`.
* **These three cannot share the switch**: `blanton_ber.sh`, `blanton_tr518.sh`, `blanton_traffic_linespeed`.
* **`FAN_SPEED` is 100.**
* **The three items listed as unverified in v1.1.0 are still unverified**: the `ce0` ingress mirror, the 120s settle in `blanton_tr518.sh`, and `test mode nr=no` on stop.
## 🔗 Links
* [ARCHITECTURE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/ARCHITECTURE.md) — test flow, data models, constraints
* [CLAUDE.md](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/CLAUDE.md) — commands and the bench gotchas
* [Blanton_Test_Flow.drawio](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/src/branch/main/docs/Blanton_Test_Flow.drawio) — the four scripts side by side
**Full changelog:** [V1.1.5...V1.1.6](https://etgit.et-wen.com/etwen/Blanton_TTL_Script/compare/V1.1.5...V1.1.6)