b652ec80728f2492e1647e3432a61dade4297c36
blanton_ber_debug.sh runs the hand-pasted flow from tools/BER_Test.txt as one command: prbs set p=p31, prbs get twice, prbsstat STArt Interval=30, sleep 40, Ber, STOp, prbs clear. Every bcmcmd output is printed as is under a timestamped header; there is no parsing, no PASS/FAIL and no summary. -u 0 / -u 1 picks one switch unit, both by default. The port list is the 200G ports without 268, as in BER_Test.txt; BER_PORTS, BER_POLY, BER_INTERVAL and BER_WAIT can be overridden. blanton_ber.sh is left unchanged. BER_Test.txt: p=3 -> p=p31 (verified on the bench), plus a unit 1 block, a both-units block and port en=0/1 for every cabled port. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_0131orciRKrejchsuDk6UpXk
Description
Blanton Tera Term TTL reliability test
4.9 MiB